📘 Product Introduction – Yokogawa AAI141-S00
The Yokogawa AAI141-S00 is a highly reliable analog input module designed for use within the CENTUM CS 3000 and CENTUM VP distributed control systems (DCS). This module specializes in processing analog signals from field instrumentation, converting them into digital data for further use in plant control and monitoring systems.
This 16-channel analog input card is capable of receiving 4 to 20 mA analog signals, ensuring high accuracy, low noise, and stable operation over long durations. Designed with industrial robustness in mind, the AAI141-S00 is built to withstand harsh operating environments, offering both durability and operational integrity in mission-critical applications.
Each channel on this module is isolated, enhancing signal quality and providing protection against electrical interference. The AAI141-S00 is hot-swappable, reducing maintenance downtime and improving system availability in continuous process plants.
🌟 Product Advantages
-
High-Density Input: Supports 16 analog input channels in a single module, allowing for compact control panel design.
-
High Accuracy: Provides precision analog signal acquisition with minimal drift and high linearity.
-
Signal Isolation: Each channel is individually isolated to prevent cross-channel interference and to enhance reliability.
-
Hot-Swappable Capability: Allows maintenance or replacement without shutting down the system, improving plant uptime.
-
Extended Temperature Range: Designed to operate in challenging environments with wide temperature tolerances.
-
Seamless Integration: Fully compatible with CENTUM VP and CS 3000 systems, ensuring easy integration and configuration.
⚙️ Technical Specifications
Parameter | Details |
---|---|
Model Number | AAI141-S00 |
Product Type | Analog Input Module |
Input Signal | 4–20 mA DC |
Number of Channels | 16 channels |
Resolution | 16-bit |
Isolation | Isolated between channels and system |
Power Supply | Supplied via base unit |
Operating Temperature | 0 to 55°C |
Storage Temperature | -20 to +70°C |
Relative Humidity | 5% to 95% (non-condensing) |
Dimensions | 107.5 × 32.8 × 130 mm |
Weight | 0.2 kg |
Mounting | Mounted on N-type base |
Voltage Range | 24 V DC (from system power supply) |
Certifications | CE, KC, UL (depending on region) |
Diagnostic Functions | Built-in self-diagnosis, loop checking |
🏭 Applications
-
Oil & Gas Plants: Monitoring and control of pressure, temperature, and flow via analog signals.
-
Chemical Processing: Accurate analog signal input for batch processing and chemical dosing systems.
-
Power Generation: Integrates with turbine and boiler control systems for real-time analog monitoring.
-
Pharmaceuticals: Ensures precision analog signal acquisition in validated environments.
-
Water Treatment Plants: Supports control of pH levels, flow meters, and pump speed monitoring.
🔗 Compatible Models
The AAI141-S00 is designed to integrate seamlessly with the following Yokogawa control system hardware:
-
Yokogawa FCS (Field Control Station) for CENTUM VP
-
Yokogawa AFV10D Base Unit
-
Yokogawa ANB10D/ANB11D Node Interface Modules
-
Yokogawa AAI841 Analog Output Modules
-
Yokogawa SAI143-S00 Intelligent Input Modules
-
Yokogawa AAI143-H50 High-Speed Analog Modules
These models provide I/O signal conditioning, communication, and base support to ensure seamless installation and operation.
🛠️ Installation Instructions
-
Power Down the System (if not hot-swapping)
Before installation, ensure the system is powered off unless hot-swap is supported. -
Mount on Base Unit
Attach the AAI141-S00 module securely to the N-type base unit, such as the AFV10D. -
Connect Field Wiring
Wire the analog input field signals (4-20 mA) into the appropriate terminal block on the base. -
Configure in Control Software
Open the CENTUM VP or CS 3000 engineering software, register the AAI141-S00 module, assign tag names, and set signal ranges. -
Power On and Verify
Restore power and verify the input values are being read correctly. Use diagnostics to confirm normal operation. -
Loop Test (if required)
Perform signal simulation or loop testing to ensure integrity of wiring and signal processing.
🔄 6 Related or Same-Series Models
Model | Description | Channels | Signal Type | Dimensions (mm) | Weight |
---|---|---|---|---|---|
AAI141-H00 | Analog Input Module (High Accuracy) | 16 | 4–20 mA DC | 27.6 × 130 × 176 | 0.3 kg |
AAI143-S00 | Isolated Analog Input Module | 8 | 4–20 mA DC | 27.6 × 130 × 176 | 0.3 kg |
AAI841-S00 | Analog Output Module | 8 | 4–20 mA DC | 27.6 × 130 × 176 | 0.3 kg |
AAI835-H00 | High-Speed Analog Input Module | 8 | 1–5 V / 4–20 mA | 27.6 × 130 × 176 | 0.3 kg |
SAI143-H00 | Smart AI Module with Diagnostics | 8 | 4–20 mA DC | 27.6 × 130 × 176 | 0.3 kg |
AAI141-S10 | Analog Input (with HART Communication) | 16 | 4–20 mA + HART | 27.6 × 130 × 176 | 0.3 kg |
🔝 8 Popular Yokogawa Models with Specifications
Model | Type | Function | Dimensions (mm) | Weight | Voltage |
---|---|---|---|---|---|
AAI141-S00 | Analog Input Module | 16-ch, 4–20 mA Input | 27.6 × 130 × 176 | 0.3 kg | 24 V DC |
AAI141-H00 | High Accuracy AI Module | 16-ch, 4–20 mA Input | 27.6 × 130 × 176 | 0.3 kg | 24 V DC |
AAI841-S00 | Analog Output Module | 8-ch, 4–20 mA Output | 27.6 × 130 × 176 | 0.3 kg | 24 V DC |
SAI143-H00 | Intelligent AI Module | 8-ch, 4–20 mA Input | 27.6 × 130 × 176 | 0.3 kg | 24 V DC |
AAI835-H00 | High-Speed AI Module | 8-ch, Voltage/Current Input | 27.6 × 130 × 176 | 0.3 kg | 24 V DC |
CP451-50 | Processor Module | CPU for Control Station | 27.6 × 130 × 176 | 0.4 kg | 24 V DC |
NFAI143-S50 | Remote AI Module | 8-ch, Remote Analog Input | 27.6 × 130 × 176 | 0.3 kg | 24 V DC |
F3LE11-0T | Expansion IO Module | 16-ch Digital Input | 27.6 × 130 × 176 | 0.35 kg | 24 V DC |
❓ Frequently Asked Questions (FAQs)
Q1: What type of signals does the AAI141-S00 support?
A1: The AAI141-S00 supports standard 4–20 mA DC analog input signals from field instrumentation such as transmitters and sensors.
Q2: Is the AAI141-S00 module hot-swappable?
A2: Yes, it supports hot-swapping, allowing replacement without shutting down the system, which enhances uptime and operational continuity.
Q3: Can this module be used with HART-enabled devices?
A3: The standard AAI141-S00 does not support HART communication. For HART functionality, you should use the AAI141-S10 variant.
Q4: How do I check the health of the module?
A4: The module includes built-in diagnostic functions that allow users to perform loop tests, check signal integrity, and monitor module status through the DCS software.
Q5: What base unit is compatible with AAI141-S00?
A5: The AAI141-S00 is mounted on an N-type base unit such as the AFV10D. Ensure proper wiring and terminal configuration for each input channel.
Q6: What is the installation orientation?
A6: It is designed to be installed vertically in a control cabinet with adequate ventilation. Make sure to leave sufficient space around the module for heat dissipation.