Yokogawa AMM12 Product Documentation
Product Introduction
The Yokogawa AMM12 is a high-performance analog multiplexer module designed for industrial automation and data acquisition systems. It serves as a reliable solution for switching and monitoring multiple analog signals in process control, test, and measurement applications.
The module is part of Yokogawa’s extensive lineup of signal conditioning and data acquisition products, known for their precision, durability, and compatibility with various industrial environments.
Product Advantages
-
High Accuracy – Provides precise signal switching with minimal interference.
-
Robust Construction – Designed to withstand harsh industrial conditions.
-
Easy Integration – Compatible with Yokogawa’s DAQ systems and third-party devices.
-
Low Crosstalk – Ensures signal integrity even in high-density configurations.
-
Wide Voltage Range – Supports various signal levels, making it versatile for different applications.
-
Modular Design – Allows for easy expansion and maintenance.
Technical Specifications
Parameter | Specification |
---|---|
Model Number | AMM12 |
Type | Analog Multiplexer Module |
Channels | 12 (Single-ended) |
Switching Speed | ≤5 ms per channel |
Input Voltage Range | ±10 V DC |
Max Current Rating | 1 A per channel |
Isolation Voltage | 250 V AC/DC (Channel-to-Channel) |
Operating Temp. | -10°C to +55°C |
Storage Temp. | -20°C to +70°C |
Humidity Range | 10% to 90% RH (Non-condensing) |
Dimensions (W×H×D) | 120 × 45 × 120 mm |
Weight | 0.45 kg |
Power Supply | 24 V DC (±10%) |
Power Consumption | 5 W (Max) |
Applications
-
Process Control Systems – Used for monitoring multiple sensor inputs in manufacturing plants.
-
Data Acquisition (DAQ) – Integrates with Yokogawa’s DAQ systems for signal routing.
-
Test & Measurement – Facilitates automated testing by switching between multiple signal sources.
-
Energy Management – Helps in monitoring power distribution systems.
-
Laboratory Equipment – Used in research setups requiring high-precision signal switching.
Compatible Models
The AMM12 can be used alongside the following Yokogawa products:
-
Yokogawa MX100 – Universal Data Acquisition System
-
Yokogawa MW100 – Multi-Function Data Logger
-
Yokogawa DLM2000 – Mixed Signal Oscilloscope
-
Yokogawa IS8000 – Integrated Monitoring System
Installation Instructions
-
Mounting – Secure the module in a DIN rail or panel-mounted enclosure.
-
Wiring – Connect input/output signals as per the terminal assignments.
-
Power Connection – Ensure proper polarity when connecting the 24 V DC supply.
-
Grounding – Use a dedicated ground terminal for noise reduction.
-
Verification – Test each channel before full operation.
Recommended Similar Models (Same Series)
Model | Type | Channels | Voltage Range | Dimensions (mm) | Weight |
---|---|---|---|---|---|
AMM16 | Analog Multiplexer | 16 | ±10 V DC | 120 × 45 × 120 | 500 g |
AMM24 | Analog Multiplexer | 24 | ±15 V DC | 150 × 45 × 120 | 600 g |
DMM12 | Digital MUX Module | 12 | 0-30 V DC | 120 × 45 × 120 | 450 g |
RMX8 | Relay Multiplexer | 8 | 250 V AC/DC | 100 × 45 × 120 | 400 g |
SMX6 | Signal Conditioner MUX | 6 | ±5 V DC | 80 × 45 × 120 | 350 g |
TMX12 | Thermocouple MUX | 12 | -50 mV to +100 mV | 120 × 45 × 120 | 470 g |
Recommended Popular Yokogawa Models
Model | Type | Key Parameters | Dimensions (mm) | Weight |
---|---|---|---|---|
WT3000 | Power Analyzer | 0.1% Accuracy, 1 MHz Bandwidth | 213 × 132 × 370 | 5.5 kg |
DL850E | ScopeCorder | 16-bit, 100 MS/s | 426 × 177 × 400 | 12 kg |
DX2000 | Paperless Recorder | 12 Channels, 24 V DC | 144 × 144 × 150 | 1.8 kg |
GM10 | Data Logger | 10 Channels, -200°C to +1370°C | 96 × 96 × 90 | 300 g |
IS8000 | Integrated Monitoring | 64 Channels, 24 V DC | 480 × 132 × 400 | 15 kg |
MX100 | DAQ System | 100 Channels, USB/Ethernet | 340 × 132 × 300 | 4.5 kg |
MW100 | Data Logger | 20 Channels, 24 V DC | 144 × 144 × 150 | 1.5 kg |
DLM4000 | Oscilloscope | 8 Channels, 500 MHz | 320 × 150 × 370 | 6.2 kg |
FAQ (Frequently Asked Questions)
Q1: What is the maximum switching voltage for the AMM12?
A1: The AMM12 supports a maximum switching voltage of ±10 V DC.
Q2: Can the AMM12 be used with thermocouple inputs?
A2: No, the AMM12 is designed for analog voltage signals. For thermocouples, consider the TMX12 model.
Q3: What is the recommended maintenance interval for the AMM12?
A3: Yokogawa recommends inspecting connections and performance every 12 months under normal operating conditions.
Q4: Does the AMM12 support daisy-chaining for expansion?
A4: Yes, multiple AMM12 units can be connected via a compatible backplane or communication interface.
Q5: What is the expected lifespan of the AMM12?
A5: Under proper operating conditions, the AMM12 has a typical lifespan of 10+ years.
Q6: Is the AMM12 compatible with third-party DAQ software?
A6: Yes, it supports standard communication protocols (e.g., Modbus) for integration with third-party systems.
Yokogawa AMM12 voltage input multiplexer module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |