Product Introduction: Yokogawa AMM21T
The Yokogawa AMM21T is a high-performance analog input module designed for use in distributed control systems (DCS), particularly within the CENTUM VP and CENTUM CS 3000 platforms. Engineered to meet the rigorous demands of industrial automation, this module facilitates precise data acquisition of analog signals from field instruments, ensuring real-time monitoring and control of plant processes.
With support for multiple analog input channels, AMM21T excels in scalability and integration. Its robust design adheres to Yokogawa’s stringent quality standards and supports a wide temperature range, making it suitable for harsh industrial environments such as oil & gas, petrochemical, power, and water treatment plants.
Each input channel is isolated and capable of handling various analog signal types, including 4–20 mA and 1–5 VDC, offering flexible configuration. The module is hot-swappable, reducing system downtime during maintenance and upgrades.
Product Advantages
-
High Accuracy: Delivers precise and stable analog input readings for mission-critical applications.
-
Channel Isolation: Individual channel isolation enhances safety and prevents interference.
-
Hot-swappable Design: Facilitates module replacement without halting system operation.
-
Wide Compatibility: Seamlessly integrates with Yokogawa’s CENTUM VP/CS 3000 DCS systems.
-
Industrial-grade Reliability: Built for 24/7 operation in demanding industrial environments.
-
Extended Temperature Range: Operates effectively in extreme temperature conditions.
Technical Specifications
Parameter | Details |
---|---|
Model Number | AMM21T |
Product Type | Analog Input Module |
Number of Channels | 16 Channels |
Input Signal Type | 4–20 mA DC, 1–5 VDC |
Resolution | 16-bit A/D conversion |
Isolation | Channel-to-channel and channel-to-ground |
Input Accuracy | ±0.1% of full scale |
Operating Voltage | 24 VDC (supplied from base unit) |
Power Consumption | 3 W |
Operating Temperature | -20°C to +60°C |
Storage Temperature | -40°C to +70°C |
Relative Humidity | 5–95% RH (non-condensing) |
Dimensions | 120 × 90 × 35mm |
Weight | 0.45kg |
Mounting Type | DIN rail or card rack installation |
Certifications | CE, UL, CSA, RoHS |
Compatibility | CENTUM VP, CENTUM CS 3000 |
Applications
-
Oil & Gas Facilities: For monitoring pressure, temperature, and flow signals from transmitters.
-
Petrochemical Plants: Provides reliable analog input for complex process control systems.
-
Power Generation Units: Ensures real-time analog feedback from turbines and auxiliary equipment.
-
Water and Wastewater Treatment: Acquires signals from pH, turbidity, and level sensors.
-
Food & Beverage Processing: Collects data for environmental and quality control parameters.
-
Pharmaceutical Manufacturing: Monitors critical process variables under GMP compliance.
Compatible Models
The AMM21T is designed to operate in conjunction with several Yokogawa modules and systems. Common compatible models include:
-
CPU Modules: AFV10D, AFV30D
-
Base Units: ANB10D, ANB11D
-
Power Supply Units: PW481, PW482
-
Other I/O Modules: AAI141, AAI143, ADV151, ADO141
-
Control Bus Modules: ACG10S, ACG30S
Installation Instructions
-
Power Down System (If Not Hot-swapping): Ensure the main power is switched off unless the system supports hot-swapping.
-
Mounting the Module: Attach the AMM21T to the designated DIN rail or secure it in the card rack using the appropriate locking clips.
-
Connect Signal Wires: Wire the field analog signals to the terminal block following the channel configuration. Ensure correct polarity and signal type.
-
Grounding: Properly ground the module using the ground terminal to prevent electrical noise and surges.
-
System Configuration: Use Yokogawa’s engineering tools to configure the module channels in the system’s logic.
-
Power Up and Test: Power on the system and verify that the module is recognized. Conduct a functional test using known signal inputs.
-
Documentation: Record the wiring configuration and update the system architecture diagram for maintenance purposes.
6 Related or Same-series Yokogawa Models
Model | Type | Channels | Signal Type | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
AAI141 | Analog Input Module | 8 | 4–20 mA | 24 VDC | 31 × 130 × 170 | 0.25 kg |
AAI143 | Analog Input Module | 16 | 1–5 VDC | 24 VDC | 31 × 130 × 170 | 0.25 kg |
ADV151 | Digital Input Module | 32 | 24 VDC (sink/source) | 24 VDC | 31 × 130 × 170 | 0.25 kg |
ADO141 | Digital Output Module | 16 | Relay contact | 24 VDC | 31 × 130 × 170 | 0.30 kg |
AAI835 | Analog Input HART | 8 | 4–20 mA HART | 24 VDC | 31 × 130 × 170 | 0.28 kg |
AAI543 | RTD Input Module | 8 | PT100, PT1000 | 24 VDC | 31 × 130 × 170 | 0.27 kg |
8 Popular Yokogawa Models
Model | Type | Function | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
CP451-50 | Processor Module | Control processor for DCS | 24 VDC | 62 × 130 × 180 | 0.45 kg |
AAI141-H50 | Analog Input HART Module | 4–20 mA + HART | 24 VDC | 31 × 130 × 170 | 0.28 kg |
AAI835-H00 | Analog Input HART Module | 8 Channels, HART support | 24 VDC | 31 × 130 × 170 | 0.28 kg |
ACG10S | Control Bus Interface | I/O communication interface | 24 VDC | 31 × 130 × 170 | 0.26 kg |
PW482 | Power Supply Module | DCS power supply | 24 VDC | 62 × 130 × 180 | 0.50 kg |
ADV551 | Digital Input Module | 64-channel sink input | 24 VDC | 62 × 130 × 170 | 0.35 kg |
F3LE11-0T | Communication Module | Ethernet communication for FAM3 | 24 VDC | 50 × 120 × 160 | 0.40 kg |
NFCP100-S00 | Controller Module | Compact controller for safety | 24 VDC | 70 × 140 × 180 | 0.55 kg |
FAQs (Q&A Format)
Q1: What is the main function of the AMM21T module?
A1: The AMM21T serves as a 16-channel analog input module for capturing process signals such as 4–20 mA or 1–5 VDC, converting them into digital values for use in DCS systems.
Q2: Can AMM21T be replaced while the system is powered?
A2: Yes, the AMM21T supports hot-swapping, allowing maintenance or replacement without system shutdown.
Q3: Is the AMM21T compatible with legacy CENTUM CS 3000 systems?
A3: Yes, it is fully compatible with both CENTUM VP and CENTUM CS 3000 architectures.
Q4: Does the AMM21T support HART communication?
A4: No, the AMM21T does not support HART. For HART-enabled analog input, models like AAI141-H50 or AAI835 should be used.
Q5: What signal isolation does the AMM21T provide?
A5: Each channel is isolated from others and from the system ground, enhancing safety and minimizing interference.
Q6: What software is used to configure AMM21T modules?
A6: Yokogawa’s engineering tools such as CENTUM VP’s SENG or PRM are used for configuration and diagnostics.
Yokogawa AMM21T INPUT MODULE
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |