Yokogawa AAP849-S00 Product Overview
The Yokogawa AAP849-S00 is a high-performance analog input module designed for industrial automation and control systems. Engineered with precision, it delivers reliable signal acquisition and accurate data transmission essential for maintaining seamless operations in various sectors, including oil & gas, chemical processing, and power generation industries. The AAP849-S00 upholds Yokogawa’s reputation for offering durable and efficient automation components that ensure high system availability and performance.
With a robust construction and compact design, the AAP849-S00 meets rigorous industrial standards and easily integrates into Yokogawa’s CENTUM and ProSafe-RS systems. It supports multiple input types and provides excellent noise immunity, making it a versatile solution for complex automation challenges.
Advantages of Yokogawa AAP849-S00
-
High Accuracy: Ensures precise analog signal measurements across a wide range of industrial applications.
-
Enhanced Reliability: Designed to withstand harsh environmental conditions, providing long-term operational stability.
-
Seamless Integration: Fully compatible with Yokogawa’s DCS and SIS platforms, promoting easy system upgrades and expansions.
-
Compact Footprint: Optimized size saves valuable panel space, supporting efficient system layouts.
-
Superior Noise Immunity: Built-in advanced filtering and protection circuits reduce errors caused by electrical interference.
-
Flexible Input Configuration: Supports a variety of analog input types, offering versatility across different process requirements.
Technical Specifications
Parameter | Specification |
---|---|
Model Number | AAP849-S00 |
Input Type | Analog (Voltage/Current) |
Input Channels | 8 Channels |
Input Signal Range | 0–10V, 4–20mA |
Resolution | 16-bit |
Input Accuracy | ±0.1% FS |
Operating Voltage | 24 VDC (±10%) |
Power Consumption | ≤ 4 W |
Dimensions | 130 × 32.8 × 127.2 mm |
Weight | 0.3 kg |
Operating Temperature | -20°C to +60°C |
Storage Temperature | -40°C to +85°C |
Relative Humidity | 5% to 95% RH (non-condensing) |
Mounting Method | DIN Rail Mounting |
Certification | CE, UL, CSA, ATEX |
Isolation | Channel-to-Channel, Channel-to-Ground |
Response Time | ≤ 100 ms |
Applications
-
Distributed Control Systems (DCS): Seamless integration for analog data acquisition.
-
Safety Instrumented Systems (SIS): Reliable performance under critical safety conditions.
-
Oil and Gas Production: Accurate monitoring of pressure, temperature, and flow.
-
Power Generation Plants: Supervising critical analog signals for system optimization.
-
Chemical Processing: Controlling and monitoring chemical reactions with precision.
-
Pharmaceutical Manufacturing: High-fidelity data acquisition for regulatory compliance.
Compatible Yokogawa Models for Integration
-
Yokogawa CPU Module: CP451-10
-
Yokogawa Baseplate: NFDV161-P50
-
Yokogawa I/O Power Supply: PW402
-
Yokogawa Digital Output Module: ADV551-P00
-
Yokogawa Analog Output Module: AAB841-S00
-
Yokogawa Remote I/O Unit: ANB10D-420
Installation Instructions
-
Preparation:
Ensure that the system is powered down before beginning installation to avoid electrical hazards. -
Mounting:
Secure the AAP849-S00 onto the designated DIN rail in a vertical orientation for optimal heat dissipation. -
Wiring:
Connect the input channels as per the wiring diagram provided in the user manual. Ensure correct polarity and secure all terminal screws firmly. -
Power Connection:
Attach the 24 VDC power supply to the designated terminal block, verifying the voltage range compatibility. -
System Configuration:
Using Yokogawa’s engineering tool, configure the AAP849-S00 channels according to your input type (voltage or current). -
Testing:
Power up the system and perform input signal simulation to ensure correct operation. Check for error indicators on the module. -
Final Validation:
Record baseline readings and validate that all inputs are recognized and processed accurately by the control system.
Recommended Related Models (Same Series/Function)
Model Number | Input Type | Channels | Dimensions (W×H×D) | Weight | Voltage |
---|---|---|---|---|---|
AAP841-S00 | Analog Input (Voltage) | 8 | 30 x 130 x 150 mm | 440 g | 24 VDC |
AAP842-S00 | Analog Input (Current) | 8 | 30 x 130 x 150 mm | 445 g | 24 VDC |
AAP843-S00 | Analog Input (mV Range) | 8 | 30 x 130 x 150 mm | 440 g | 24 VDC |
AAP847-S00 | Analog Input (Thermocouple) | 8 | 30 x 130 x 150 mm | 450 g | 24 VDC |
AAP848-S00 | Analog Input (RTD) | 8 | 30 x 130 x 150 mm | 450 g | 24 VDC |
AAP850-S00 | Universal Analog Input | 8 | 30 x 130 x 150 mm | 455 g | 24 VDC |
Recommended 8 Popular Yokogawa Models
Model Number | Type | Function | Dimensions (W×H×D) | Weight | Voltage |
---|---|---|---|---|---|
CP451-10 | CPU Module | Central Processor Unit | 50 x 150 x 160 mm | 900 g | 24 VDC |
PW402 | Power Supply Module | System Power Supply | 40 x 150 x 150 mm | 800 g | 24 VDC |
ADV551-P00 | Digital Output Module | 32-Channel DO Module | 30 x 130 x 150 mm | 430 g | 24 VDC |
AAI543-S00 | Analog Input Module | 16-Channel AI Module | 30 x 130 x 150 mm | 450 g | 24 VDC |
AAP841-S00 | Analog Input Module | 8-Channel Voltage Input Module | 30 x 130 x 150 mm | 440 g | 24 VDC |
ANB10D-420 | Remote I/O Unit | Remote Terminal I/O Interface | 120 x 200 x 150 mm | 2.5 kg | 24 VDC |
ADV151-P00 | Digital Input Module | 32-Channel DI Module | 30 x 130 x 150 mm | 430 g | 24 VDC |
NFAI143-S50 | Analog Input Module | Remote AI with HART Communication | 30 x 130 x 150 mm | 450 g | 24 VDC |
FAQ (Frequently Asked Questions)
Q1: What input types does the AAP849-S00 support?
A1: The AAP849-S00 supports standard analog input signals, including 0–10V voltage and 4–20mA current signals.
Q2: Can the AAP849-S00 be used in hazardous environments?
A2: Yes, it has ATEX certification and is suitable for use in hazardous and explosive environments when properly installed.
Q3: How many input channels are available on the AAP849-S00?
A3: The AAP849-S00 provides 8 individual analog input channels.
Q4: Is the AAP849-S00 compatible with ProSafe-RS safety systems?
A4: Yes, it is fully compatible with Yokogawa’s ProSafe-RS Safety Instrumented Systems (SIS).
Q5: What is the recommended installation method for the AAP849-S00?
A5: It is recommended to install the AAP849-S00 on a DIN rail inside a control panel to ensure proper mechanical support and environmental protection.
Q6: How should maintenance be conducted on the AAP849-S00?
A6: Maintenance should include periodic inspection of wiring, cleaning dust from the module, and verifying module health status via system diagnostics.