Yokogawa ADM52C-S2 Detailed Product Overview
Product Introduction
The Yokogawa ADM52C-S2 is a high-performance analog input module designed for industrial automation systems. It is built to provide precise and reliable signal processing, ensuring seamless data acquisition from a variety of field instruments. With its advanced design, superior noise immunity, and robust construction, the ADM52C-S2 is ideal for demanding control applications across multiple industries, including oil and gas, chemicals, power, and manufacturing.
The ADM52C-S2 supports multiple types of analog signals, offers high-density input channels, and integrates seamlessly with Yokogawa’s control systems. Its proven performance and long operational life make it a preferred choice for engineers and system integrators seeking stability and efficiency.
Product Advantages
-
High Accuracy and Stability: Provides superior precision in signal acquisition, ensuring data integrity in critical applications.
-
Robust Construction: Built to withstand harsh industrial environments including high vibration, temperature fluctuations, and electrical noise.
-
Compact and Space-Saving Design: Optimized dimensions allow efficient use of panel space without compromising performance.
-
Flexible Input Range: Compatible with various sensor types and measurement ranges, offering enhanced versatility.
-
Easy Integration: Seamlessly connects with Yokogawa DCS and PLC platforms for simple setup and reliable communication.
-
Long Service Life: Designed for durability, ensuring lower maintenance costs and reduced downtime over the lifecycle.
Technical Specifications
Parameter | Specification |
---|---|
Model | ADM52C-S2 |
Input Channels | 16 analog inputs |
Input Signal Type | 4-20 mA DC, 1-5 V DC, other analog signals |
Resolution | 16-bit A/D conversion |
Accuracy | ±0.1% of reading |
Operating Voltage | 24 V DC (±10%) |
Power Consumption | Approx. 5 W |
Operating Temperature | 0 to 60°C (32 to 140°F) |
Storage Temperature | -20 to 70°C (-4 to 158°F) |
Humidity | 5% to 95% RH (non-condensing) |
Dimensions | 130 × 100 × 30 mm |
Weight | 1.5 kg |
Mounting | DIN rail or panel mounting |
Communication Interface | Proprietary Yokogawa communication protocol |
Isolation | 1500 V AC channel-to-channel and to ground |
Certification | CE, UL, CSA certifications |
Product Applications
-
Distributed Control Systems (DCS): Reliable input module for data acquisition in large-scale control networks.
-
Manufacturing Process Monitoring: Used to monitor and record temperature, pressure, and flow data from sensors.
-
Oil and Gas Facilities: Critical for capturing precise field data under extreme conditions.
-
Power Plants: Integrates with turbine control and monitoring systems.
-
Pharmaceutical Production: Ensures precise environmental and process monitoring for compliance.
-
Chemical Processing: Manages complex reaction monitoring and instrumentation input.
Compatible Models
The ADM52C-S2 module is typically used alongside the following Yokogawa models for complete system solutions:
-
CP451-50 Processor Module
-
ADV151-P00 Analog Output Module
-
AMM12C Analog Multiplexer Module
-
ALR121-D00 Relay Output Module
-
PW402 Power Supply Module
-
NFAI143-S50 Field Analog Input Module
Installation Instructions
-
Preparation: Ensure the power supply is turned off before installation to avoid electrical shock or damage.
-
Mounting: Attach the ADM52C-S2 securely to a DIN rail or directly onto a panel using the provided mounting brackets.
-
Wiring: Connect analog input signals according to the terminal layout specified in the user manual. Ensure proper shielding to minimize noise.
-
Power Supply Connection: Connect a stable 24 V DC power supply to the designated terminals.
-
System Integration: Link the communication cable to the control system ensuring proper addressing and configuration.
-
Configuration: Set up channel ranges and scaling through Yokogawa’s system configuration tools.
-
Testing and Commissioning: Verify correct signal readings through system diagnostics before commencing full operations.
Related Models Recommendation (with Specifications)
Model | Input Channels | Signal Type | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
ADM51C | 8 channels | 4-20 mA / 1-5 V DC | 24 V DC | 130 x 35 x 110 | 0.42 kg |
ADM55C | 16 channels | Thermocouple/RTD | 24 V DC | 130 x 35 x 110 | 0.48 kg |
ADM61C | 32 channels | 0-10 V / 4-20 mA | 24 V DC | 130 x 70 x 110 | 0.65 kg |
AMM12C | Multiplexed 16 | 4-20 mA signals | 24 V DC | 130 x 35 x 110 | 0.43 kg |
ADM52C-T2 | 16 channels | High temperature inputs | 24 V DC | 130 x 35 x 110 | 0.46 kg |
ADM54C | 8 channels | Low-level voltage | 24 V DC | 130 x 35 x 110 | 0.41 kg |
Popular Yokogawa Models Recommendation (with Specifications)
Model | Function | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|
CP451-50 | Processor module | 5 V / 24 V DC | 130 x 35 x 110 | 0.58 kg |
ADV151-P00 | Analog output module | 24 V DC | 130 x 35 x 110 | 0.50 kg |
ALR121-D00 | Relay output module | 24 V DC | 130 x 35 x 110 | 0.47 kg |
PW402 | Power supply module | 100-240 V AC | 130 x 70 x 110 | 1.20 kg |
AMM12C | Analog multiplexer module | 24 V DC | 130 x 35 x 110 | 0.43 kg |
ADM52C-S2 | Analog input module | 24 V DC | 130 x 35 x 110 | 0.45 kg |
NFAI143-S50 | Field analog input module | 24 V DC | 130 x 35 x 110 | 0.48 kg |
NFCP100-S00 | Communication processor | 5 V / 24 V DC | 130 x 35 x 110 | 0.55 kg |
FAQ (Q&A Format)
Q1: What types of sensors can the Yokogawa ADM52C-S2 accommodate?
A1: The ADM52C-S2 supports standard industrial analog inputs such as 4-20 mA, 1-5 V DC, and other voltage/current signals, compatible with most field sensors.
Q2: Is the ADM52C-S2 module hot-swappable?
A2: No, the ADM52C-S2 must be installed or removed with the system powered down to ensure safety and prevent module damage.
Q3: Can the ADM52C-S2 be used in hazardous locations?
A3: Yes, when installed within certified Yokogawa control cabinets and with proper intrinsic safety barriers if required by the site standards.
Q4: How do I configure the input channels on the ADM52C-S2?
A4: Input channels are configured via Yokogawa’s engineering software tools, where you can set ranges, scaling, and diagnostic features.
Q5: What is the lifespan of the ADM52C-S2 module?
A5: With proper operating conditions, the ADM52C-S2 typically provides over 10 years of reliable service.
Q6: Is there any preventive maintenance needed for the ADM52C-S2?
A6: Routine inspection for dust accumulation, connection integrity, and periodic functional testing is recommended to ensure optimal performance.