Yokogawa AAP149-S00 Product Overview
The Yokogawa AAP149-S00 is a high-performance analog output module designed for integration within Yokogawa’s highly reliable and scalable control systems. Built with precision engineering, the AAP149-S00 provides robust and accurate analog signal output, enabling seamless control of actuators and other field devices in industrial applications. Its superior design ensures stable long-term performance, minimizing the need for maintenance while enhancing overall plant efficiency.
Specifically tailored for critical industrial processes, this module offers exceptional reliability, precise voltage/current output control, and is compliant with stringent industry standards. It is commonly utilized in sectors such as oil and gas, chemicals, power generation, and water treatment plants, where system reliability and accuracy are paramount.
Product Advantages
-
High Accuracy: Ensures precise analog output control, critical for stable process operations.
-
Robust Reliability: Designed to operate in harsh industrial environments with excellent long-term stability.
-
Easy Integration: Seamlessly integrates with Yokogawa’s DCS and PLC systems.
-
Compact Design: Space-saving form factor allowing for high-density system configurations.
-
Energy Efficient: Optimized circuitry reduces power consumption without compromising performance.
-
Maintenance Friendly: Built-in diagnostic features support predictive maintenance strategies.
-
Compliance with Standards: Meets global industrial certifications ensuring safety and interoperability.
Technical Specifications
Parameter | Specification |
---|---|
Model | AAP149-S00 |
Output Type | Analog (Voltage/Current selectable) |
Number of Channels | 8 channels |
Output Voltage Range | 0–10 VDC |
Output Current Range | 4–20 mA |
Resolution | 12-bit |
Accuracy | ±0.1% of full scale |
Isolation | Channel to Channel, Channel to Ground |
Operating Voltage | 24 VDC (±10%) |
Power Consumption | 5 W |
Operating Temperature | 0 to 60°C (32 to 140°F) |
Storage Temperature | -20 to 85°C (-4 to 185°F) |
Humidity | 5% to 95% RH (non-condensing) |
Dimensions | 127.2 x 32.8 x 130mm |
Weight | 0.3 kg |
Mounting | DIN Rail or Panel Mount |
Certifications | CE, RoHS, UL |
Applications
-
Oil and Gas Industry: For process control in refineries and offshore platforms.
-
Chemical Plants: Precision analog control for complex chemical processes.
-
Power Generation: Managing turbine and boiler operations.
-
Water and Wastewater Treatment: Regulating chemical dosing and water flow control.
-
Pharmaceutical Manufacturing: Accurate environmental control within cleanrooms.
-
Food and Beverage Industry: For precise temperature and process control systems.
Compatible Models for System Integration
-
Yokogawa CP451-50 – CPU Module for advanced process control
-
Yokogawa NFAI143-S50 – Analog Input Module
-
Yokogawa ADV151-P00 – Digital Output Module
-
Yokogawa AAI143-S00 – Analog Input Module (4–20 mA input)
-
Yokogawa ALR121-S10 – Relay Output Module
-
Yokogawa SAI533-H00 – Serial Communication Module
Installation Instructions
-
Preparation: Verify that the working environment is free from dust, humidity, and excessive vibration. Ensure that the control system is powered down before installation.
-
Mounting: Secure the AAP149-S00 module onto a standard DIN rail or fix it onto a panel using the designated mounting holes. Ensure firm and vibration-resistant mounting.
-
Wiring: Connect the analog output wiring to the corresponding terminal blocks following the wiring diagram provided in the Yokogawa installation manual. Use shielded cables for analog signals to prevent noise interference.
-
Configuration: Using the system configuration software, assign the proper channel settings (voltage/current) and scaling for each analog output.
-
Verification: After wiring and configuration, perform a functional test to ensure all channels are correctly outputting signals within the expected ranges.
-
Commissioning: Integrate the module into the larger control system, download settings, and begin controlled operation under observation to validate system performance.
-
Maintenance Notes: Periodically inspect connection integrity and perform output calibration checks to maintain optimal system accuracy.
6 Related Yokogawa Models
Model | Description | Channels | Output Type | Voltage Range | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
AAP135-S00 | Analog Output Module | 8 | Voltage | 0–10 V | 50×100×130 | 330 g |
AAP145-S00 | Analog Output Module | 8 | Current | 4–20 mA | 50×100×130 | 340 g |
AAI143-S00 | Analog Input Module | 8 | Current | 4–20 mA | 50×100×130 | 320 g |
ADV151-P00 | Digital Output Module | 16 | Digital | N/A | 50×100×130 | 310 g |
ALR121-S10 | Relay Output Module | 8 | Relay | N/A | 50×100×130 | 350 g |
SAI533-H00 | Serial Communication Module | 2 Ports | RS-232/RS-485 | N/A | 50×100×130 | 360 g |
8 Popular Yokogawa Models
Model | Description | Main Function | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
CP451-50 | CPU Module | Control Processing | 24 VDC | 50×100×130 | 400 g |
ADV551-P03 | Digital Input Module | Digital Sensing | 24 VDC | 50×100×130 | 320 g |
ADV151-P00 | Digital Output Module | Digital Actuation | 24 VDC | 50×100×130 | 310 g |
AAI143-S00 | Analog Input Module | Analog Sensing | 24 VDC | 50×100×130 | 320 g |
AAP135-S00 | Analog Output Module | Voltage Output | 24 VDC | 50×100×130 | 330 g |
SAI533-H00 | Serial Communication Module | RS Communication | 24 VDC | 50×100×130 | 360 g |
NFAI143-S50 | Advanced Analog Input Module | Enhanced Accuracy | 24 VDC | 50×100×130 | 340 g |
ALR121-S10 | Relay Output Module | Relay Control | 24 VDC | 50×100×130 | 350 g |
FAQ (Frequently Asked Questions)
Q1: What is the main function of the Yokogawa AAP149-S00 module?
A1: The AAP149-S00 is designed to output precise analog signals (voltage or current) to control various field devices such as actuators, valves, and motors.
Q2: Can the AAP149-S00 module handle both voltage and current output?
A2: Yes, the module supports selectable output between voltage (0–10 VDC) and current (4–20 mA), configurable via system settings.
Q3: What type of mounting is required for the AAP149-S00?
A3: The module can be mounted on a DIN rail or directly onto a panel using standard mounting procedures.
Q4: Is the AAP149-S00 suitable for harsh environments?
A4: Yes, it is built with industrial-grade components and complies with CE, RoHS, and UL certifications, ensuring reliable operation in demanding conditions.
Q5: How often should calibration be performed on the AAP149-S00?
A5: It is recommended to perform calibration checks annually or whenever the system indicates potential output deviations during maintenance checks.
Q6: What precautions should be taken during wiring installation?
A6: Ensure that shielded cables are used for analog signals, connections are tight, and the system is powered down to avoid electrical hazards.