Schneider BMXAMI0410 Analog Input Module
Product Introduction
The Schneider Electric BMXAMI0410 is an analog input module from the Modicon M340 series. It is designed to enhance process control systems by accurately acquiring analog signals from various field devices such as sensors and transmitters. Featuring four isolated analog current inputs, this module ensures signal integrity and high performance in industrial automation environments.
The module supports 0-20 mA and 4-20 mA analog input signals, offering high resolution and stability for precise data collection. It is ideal for applications requiring robust signal processing and noise immunity, particularly in demanding industrial sectors such as manufacturing, water treatment, oil and gas, and food processing.
Each input is electrically isolated, which helps reduce cross-talk and potential damage from field interference or wiring faults. With its compact design and integration-friendly architecture, the BMXAMI0410 allows for seamless installation into Modicon M340 racks and contributes to scalable, flexible automation systems.
Product Advantages
-
High Accuracy and Resolution
Provides 14-bit resolution for precise signal acquisition, supporting critical process control functions. -
Galvanic Isolation
Each analog input channel is individually isolated, protecting both the module and the control system from electrical disturbances. -
Current Loop Compatibility
Compatible with both 0-20 mA and 4-20 mA signal ranges, commonly used in industrial instrumentation. -
Compact and Modular
Easily integrates into the M340 rack system, allowing for flexible expansion in automation projects. -
Robust Industrial Design
Built to withstand industrial environmental conditions such as vibration, electrical noise, and temperature variations. -
LED Diagnostics
Front-panel LEDs provide real-time diagnostics for channel status and module health.
Technical Specifications
Parameter | Details |
---|---|
Product Type | Analog Input Module |
Module Reference | BMXAMI0410 |
Input Type | 4 isolated analog current inputs |
Input Signal Range | 0-20 mA / 4-20 mA |
Resolution | 14 bits |
Isolation | Channel-to-bus and channel-to-channel |
Conversion Time | 2.5 ms/channel |
Accuracy | ±0.2% of full scale |
Diagnostic Functions | Channel status, module error |
Voltage Supply | 24 V DC (via rack) |
Dimensions | 93 x 33 x 104 mm |
Weight | 0.15 kg |
Operating Temperature | 0 to 60 °C |
Storage Temperature | -40 to 85 °C |
Relative Humidity | 5% to 95% (non-condensing) |
Mounting | DIN rail or rack mount |
Bus Compatibility | Modicon M340 backplane |
Applications
The Schneider BMXAMI0410 is widely used across a variety of industrial and infrastructure sectors where analog signal monitoring is essential:
-
Water and Wastewater Management Systems
-
Oil and Gas Process Monitoring
-
HVAC and Environmental Control
-
Manufacturing and Assembly Lines
-
Food and Beverage Production
-
Pharmaceutical Batch Processing
-
Power Plant Instrumentation
-
Building Management Systems (BMS)
Compatible Modules and Models
The BMXAMI0410 is part of the Modicon M340 family and is designed to work in conjunction with the following types of modules and accessories:
-
BMXP34 CPUs – Programmable controllers for logic and process control
-
BMXCPS3500/3540 – Power supply modules for M340 racks
-
BMXCRA31210 / BMXCRA31200 – Communication modules for Ethernet and Modbus
-
BMXNOE0100 – Ethernet communication module
-
BMXFTB2010 – Terminal blocks for signal wiring
-
BMXXBP0x00 – Backplane modules in various slot configurations (2, 4, 6, 8, 12)
Installation Instructions
-
Power Off the System:
Ensure that the entire PLC system is powered down before beginning installation to avoid electrical hazards. -
Mount the Module:
Insert the BMXAMI0410 module into a compatible slot in the M340 backplane. Secure it using the side latches until a click is heard. -
Connect Terminal Block:
Attach the appropriate terminal block (e.g., BMXFTB2010) to the module to wire the analog inputs. -
Wire Analog Signals:
Connect analog signal sources (transmitters, sensors) to the terminal block following the 0-20 mA or 4-20 mA wiring diagram. -
Check Isolation and Grounding:
Confirm that all field instruments are properly isolated and grounded to reduce noise and prevent damage. -
Power On and Configure:
Re-power the PLC system. Use Unity Pro / EcoStruxure Control Expert to configure input ranges, diagnostics, and assign tags. -
Validation and Testing:
Validate all inputs through software tools and verify signal integrity through live diagnostics.
6 Related Models in the Same Series
Model | Type | Input/Output | Signal Type | Dimensions (mm) | Weight |
---|---|---|---|---|---|
BMXAMI0800 | Analog Input Module | 8 analog inputs | Voltage (0–10 V) | 98 x 32 x 87 | 180 g |
BMXAMI0810 | Analog Input Module | 8 analog inputs | Current (4–20 mA) | 98 x 32 x 87 | 180 g |
BMXAMO0410 | Analog Output Module | 4 analog outputs | Current (4–20 mA) | 98 x 32 x 87 | 180 g |
BMXAMO0802 | Analog Output Module | 8 analog outputs | Voltage/Current | 98 x 32 x 87 | 180 g |
BMXERT1604 | Discrete Output Module | 16 transistor outputs | 24 V DC | 98 x 32 x 87 | 180 g |
BMXDDI3202K | Digital Input Module | 32 digital inputs | 24 V DC | 98 x 32 x 87 | 180 g |
8 Popular Schneider Models
Model | Type | Input/Output | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
BMXP342020 | CPU Module | N/A | 24 V DC | 98 x 62 x 87 | 300 g |
BMXDDO3202K | Digital Output Module | 32 outputs | 24 V DC | 98 x 32 x 87 | 180 g |
BMXCPS3500 | Power Supply Module | N/A | 24 V DC | 98 x 32 x 87 | 180 g |
BMXNOE0100 | Ethernet Communication | N/A | 24 V DC | 98 x 32 x 87 | 180 g |
BMXNOM0200 | Serial Communication | N/A | 24 V DC | 98 x 32 x 87 | 180 g |
BMXDRA1605 | Relay Output Module | 16 relay outputs | 250 V AC / 30 V DC | 98 x 32 x 87 | 200 g |
BMXFTB2010 | Terminal Block | For I/O wiring | N/A | Varies | 120 g |
BMXXBP0400 | Backplane (4-slot) | For module mounting | N/A | 118 x 175 x 87 | 400 g |
Frequently Asked Questions (FAQ)
Q1: What is the primary function of the BMXAMI0410?
A1: The BMXAMI0410 is designed to receive analog current signals (0–20 mA or 4–20 mA) from field devices such as sensors and transmitters and convert them into digital signals for processing by a Modicon M340 PLC system.
Q2: Can this module be used with voltage input signals?
A2: No, the BMXAMI0410 specifically supports only current-type analog signals. For voltage input signals (e.g., 0–10 V), Schneider offers other models such as the BMXAMI0800.
Q3: Is channel-to-channel isolation provided?
A3: Yes, each of the four analog input channels on the BMXAMI0410 is electrically isolated, ensuring high reliability and reducing the risk of signal interference.
Q4: What software is used to configure this module?
A4: The BMXAMI0410 can be configured using Schneider’s Unity Pro software, now integrated into EcoStruxure Control Expert.
Q5: How is the wiring done for a 4-20 mA loop-powered sensor?
A5: For a loop-powered 4–20 mA sensor, connect the positive lead to the analog input terminal and the negative lead to the common. Ensure proper grounding to avoid noise.
Q6: What happens if an input channel is open or disconnected?
A6: The module has built-in diagnostics to detect open loops or disconnections, which will trigger a fault indication via LED and be flagged in the PLC software.
Schneider BMXAMI0410 Analog isolation high level input module