Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Introduction – Schneider Electric 140DDO35301
The Schneider Electric 140DDO35301 is a high-performance discrete output module specifically engineered for the Modicon Quantum automation platform. Designed to handle digital signal outputs, this module features 32 discrete output channels, offering robust industrial control for on/off operations. Utilizing 24V DC voltage with positive logic, the module ensures accurate and fast switching for various actuators such as relays, contactors, and indicator lamps.
As a core component in programmable logic controller (PLC) architectures, the 140DDO35301 serves mission-critical automation systems in industries such as oil & gas, water treatment, mining, and manufacturing. Its plug-and-play capability and high-density channel configuration provide users with a scalable and efficient I/O solution, ideal for modern industrial requirements.
Product Advantages
-
High Channel Density: Offers 32 digital output channels in a compact single-slot module, optimizing cabinet space.
-
Modicon Quantum Compatibility: Seamlessly integrates into Schneider Electric’s Quantum series PLC racks, providing smooth operation within existing systems.
-
LED Diagnostics: Equipped with per-point LED indicators for real-time output status monitoring and quick troubleshooting.
-
Industrial Grade Reliability: Designed to operate under harsh industrial environments with high immunity to electromagnetic interference and voltage fluctuations.
-
Simple Maintenance: Hot-swappable design enables module replacement without shutting down the system, reducing downtime.
-
Safety Assurance: Features short-circuit protection and overcurrent diagnostics to safeguard both module and connected field devices.
Technical Specifications
Parameter | Description |
---|---|
Part Number | 140DDO35301 |
Manufacturer | Schneider Electric |
Product Type | Discrete Output Module |
Number of Channels | 32 |
Output Voltage | 24V DC |
Logic Type | Positive |
Output Current per Channel | 0.5 A |
Total Module Current | 16 A max |
Response Time | < 1 ms |
Isolation Voltage | 1780 V RMS |
Diagnostics | LED per channel, short-circuit detection |
Backplane Current Consumption | 410 mA |
Operating Temperature | 0°C to 60°C |
Storage Temperature | -40°C to 85°C |
Humidity | 5% to 95% non-condensing |
Dimensions | 103.9 × 40.3 × 250 mm |
Weight | 0.45 kg |
Mounting Type | Rack-mounted (Quantum backplane) |
Hot-Swappable | Yes |
Compliance Standards | CE, UL, CSA, RoHS |
Product Applications
The Schneider 140DDO35301 is used across a wide range of industrial automation and control systems, including:
-
Manufacturing Automation: Controls actuators, solenoids, and signal indicators in assembly lines.
-
Water & Wastewater Treatment: Manages pumps, valves, and alarm systems in treatment plants.
-
Oil and Gas: Used in offshore platforms and refineries for precise digital output control in hazardous zones.
-
Power Generation: Assists in controlling relay circuits and switching sequences in power plants.
-
Pharmaceutical Industry: Ensures output accuracy and equipment synchronization in production lines.
-
Food & Beverage Plants: Coordinates control of packaging and processing machinery.
Compatible Models / Accessories
The 140DDO35301 can be used with various components in the Modicon Quantum series, including:
-
140CPU65160 – High-speed CPU module
-
140ACI03000 – Analog current input module
-
140XBP00600 – 6-slot Quantum backplane
-
140CPS11420 – Power supply module
-
140DDI35300 – Discrete input module
-
140CRP93100 – Remote I/O drop adapter
Installation Instructions
-
Power Off the Rack: Before installation, ensure the PLC system is powered down to prevent electrical hazards.
-
Align the Module: Insert the 140DDO35301 into an available slot on the Quantum backplane. Ensure the module aligns properly with the guide rails.
-
Secure the Module: Press the module firmly into the slot until the connector mates completely, then lock it using the top and bottom retention screws.
-
Wiring the Outputs: Connect field wiring to the 40-pin connector following the wiring diagram provided in the user manual. Use shielded cables where necessary.
-
Power On and Test: Reapply power to the rack and observe the LED indicators. Perform a functional output test via PLC programming software.
-
Diagnostics Check: Confirm that all channels respond appropriately and verify no fault indicators are active.
6 Related Models (Same or Related Series)
Model | Description | Channels | Voltage | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|---|
140DDO35300 | Discrete Output Module, 32 ch, sink type | 32 | 24V DC | 129 x 35 x 186 | 0.31 |
140DDO84300 | Discrete Output, 16 ch, relay contact | 16 | 24V DC | 129 x 35 x 186 | 0.38 |
140DDI35300 | Discrete Input Module, 32 ch, source type | 32 | 24V DC | 129 x 35 x 186 | 0.32 |
140DRA84000 | Relay Output Module, 8-channel | 8 | 24-230V AC | 129 x 35 x 186 | 0.36 |
140DDI84100 | Discrete Input Module, 16 ch, 120V AC | 16 | 120V AC | 129 x 35 x 186 | 0.33 |
140DAO84000 | Analog Output Module, 8 ch | 8 | 0-20 mA | 129 x 35 x 186 | 0.34 |
8 Popular Schneider Models
Model | Description | Type | Voltage | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|---|
140CPU65160 | PLC CPU module, 166 MHz | CPU | 5V DC | 129 x 66 x 186 | 0.45 |
140XBP01600 | 16-slot Quantum backplane | Rack | — | 129 x 432 x 186 | 0.75 |
140CPS11420 | Power Supply Module, 115/230V AC | Power Supply | 115/230V AC | 129 x 66 x 186 | 0.65 |
140ACI03000 | Analog Input Module, 8 channels, current | Analog Input | 0-20 mA | 129 x 35 x 186 | 0.34 |
BMXDDO1602 | Discrete Output Module, 16 ch | Discrete Output | 24V DC | 100 x 30 x 115 | 0.25 |
TM241CE40T | Logic controller with Ethernet, 24 I/Os | Controller | 24V DC | 90 x 100 x 70 | 0.4 |
BMXP342020 | Processor Module, Modicon M340 | CPU | 24V DC | 100 x 60 x 130 | 0.38 |
TM3DI16K | Discrete Input Module for M221/M241 | Discrete Input | 24V DC | 90 x 45 x 70 | 0.20 |
Frequently Asked Questions (FAQ)
Q1: What type of devices can be connected to the 140DDO35301 output channels?
A1: You can connect devices such as solenoids, indicator lights, relays, and contactors that operate with 24V DC logic.
<br>
Q2: Is the 140DDO35301 compatible with Modicon M340 or M580 systems?
A2: No, the 140DDO35301 is specifically designed for the Modicon Quantum series and is not directly compatible with M340 or M580 without a protocol bridge or adapter.
<br>
Q3: Can this module be replaced without shutting down the entire PLC system?
A3: Yes, it supports hot-swapping, allowing for safe removal and installation while the system is powered.
<br>
Q4: Does the module have built-in diagnostics for troubleshooting?
A4: Yes, it includes individual LED indicators for each channel and provides fault diagnostics such as short-circuit detection.
<br>
Q5: What is the maximum current load that the entire module can handle?
A5: The total current load for the entire module should not exceed 16 A, with a maximum of 0.5 A per output channel.
<br>
Q6: What maintenance is required for long-term operation?
A6: Routine inspections for dust, wire integrity, and verification of LED diagnostics are recommended. Also ensure firmware/software configurations remain up to date.
<br>
Schneider 140DDO35301 Discrete output modules
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |