Schneider 140DDI67300 Product Overview
The Schneider 140DDI67300 is a high-performance discrete input module designed for the Modicon Quantum automation platform. This module offers reliable digital input processing for industrial control systems. Engineered for critical industrial environments, the 140DDI67300 module ensures optimal data acquisition and transmission with high-speed response, robust build quality, and superior EMC (Electromagnetic Compatibility) performance. It supports 32 discrete inputs at 24 VDC and is ideal for monitoring switch statuses, sensor outputs, and other digital signals across complex process applications.
With its plug-and-play modular architecture, the 140DDI67300 simplifies maintenance and expansion, making it a preferred choice for large-scale automation systems.
Product Advantages
-
High Input Density: Provides 32 digital input points, maximizing I/O capacity per module.
-
Robust Performance: Designed for harsh industrial conditions with excellent resistance to electrical noise.
-
Fast Response Time: Quick signal acquisition ensures timely process control and monitoring.
-
Wide Compatibility: Seamlessly integrates with the Modicon Quantum range and Unity Pro software.
-
Easy Diagnostics: Features LED indicators for fast troubleshooting and status monitoring.
-
Space Efficient: Compact design saves panel space, allowing for higher density installations.
-
Long Operational Life: High-quality components ensure reliability and extended module lifespan.
Technical Specifications
Specification | Detail |
---|---|
Product Type | Discrete Input Module |
Series | Modicon Quantum |
Input Channels | 32 discrete inputs |
Input Voltage | 24 VDC |
Input Voltage Range | 19 to 30 VDC |
Isolation Voltage | 1780 Vrms between channels and bus |
Input Current | 6.3 mA at 24 VDC |
Response Time | ON: ≤ 1 ms / OFF: ≤ 1 ms |
Input Threshold Voltage | Logic 1: ≥ 11 VDC; Logic 0: ≤ 5 VDC |
Dimensions | 103.9 × 40.3 × 250 mm |
Weight | 0.3 kg |
Power Dissipation | 4.5 W |
Mounting Type | Backplane mounting |
Operating Temperature | 0°C to 60°C |
Storage Temperature | -40°C to 85°C |
Relative Humidity | 5% to 95% non-condensing |
Vibration Resistance | 3 gn |
Shock Resistance | 30 gn |
Certifications | CE, UL, CSA, ATEX |
Applications
-
Manufacturing Automation: Ideal for controlling machinery and production lines.
-
Oil & Gas: Suitable for monitoring critical input signals from field instruments.
-
Water and Wastewater Management: Enables real-time monitoring of valve positions, pump statuses, and sensors.
-
Power Generation: Supports complex control and safety systems.
-
Food & Beverage: Ensures consistent operation and monitoring of automated systems.
-
Pharmaceuticals: Used in regulated environments for precise input acquisition and documentation.
Compatible Models
-
140CPU65160 – Quantum CPU module
-
140CRA31200 – Remote I/O Adapter Module
-
140ACI04000 – Analog Current Input Module
-
140DAI74000 – Discrete Input Module 120 VAC
-
140NOE77101 – Ethernet Communication Module
-
140CRP93100 – RIO Drop Adapter
Installation Instructions
-
Preparation: Ensure power is off before installing the 140DDI67300 module.
-
Module Insertion: Align the module with the designated slot on the Quantum backplane and firmly push it into position until it locks.
-
Wiring: Connect discrete input wiring to the removable terminal blocks. Verify polarity and ensure secure, clean connections.
-
Configuration: Use Unity Pro or EcoStruxure Control Expert software to configure the module settings, assign addresses, and enable diagnostics.
-
Testing: Power up the system and verify input signals via module LEDs and software diagnostics.
-
Maintenance: Periodically inspect for dust, loose connections, or corrosion. Follow Schneider’s maintenance recommendations.
Recommended 6 Related Models
Model | Description | Input Type | Channels | Voltage | Size (mm) | Weight (kg) |
---|---|---|---|---|---|---|
140DDI35300 | Discrete Input Module, 24 VDC Sink | 16 Inputs | 24 VDC | 50 x 400 x 300 | 0.9 | |
140DDI84100 | Discrete Input Module, 24 VDC Source | 64 Inputs | 24 VDC | 50 x 400 x 300 | 1.1 | |
140DDI55300 | Discrete Input Module, 24 VDC Sink | 32 Inputs | 24 VDC | 50 x 400 x 300 | 0.95 | |
140DDO35300 | Discrete Output Module, 24 VDC Sink | 16 Outputs | 24 VDC | 50 x 400 x 300 | 1.0 | |
140DDO55300 | Discrete Output Module, 24 VDC Source | 32 Outputs | 24 VDC | 50 x 400 x 300 | 1.05 | |
140DAI35300 | Discrete Input Module, 120 VAC | 16 Inputs | 120 VAC | 50 x 400 x 300 | 1.0 |
Recommended 8 Popular Schneider Models
Model | Description | Type | Voltage | Size (mm) | Weight (kg) |
---|---|---|---|---|---|
140CPU65150 | Quantum CPU, Ethernet | CPU Module | 24 VDC | 50 x 400 x 300 | 1.2 |
140NOE77101 | Ethernet Communication Module | Comm Module | 24 VDC | 50 x 400 x 300 | 0.9 |
140CRA31200 | Remote I/O Adapter | I/O Adapter | 24 VDC | 50 x 400 x 300 | 1.0 |
140ACI04000 | Analog Current Input Module | Analog Input | 24 VDC | 50 x 400 x 300 | 1.0 |
140AII33000 | Analog Voltage Input Module | Analog Input | 24 VDC | 50 x 400 x 300 | 1.0 |
140DAO85300 | Analog Output Module, 0-20 mA | Analog Output | 24 VDC | 50 x 400 x 300 | 1.1 |
140DDO35300 | Discrete Output Module, 24 VDC Sink | Discrete Output | 24 VDC | 50 x 400 x 300 | 1.0 |
140CPS11420 | Power Supply Module | Power Supply | 24 VDC / 115VAC | 50 x 400 x 300 | 1.3 |
140DDI67300 FAQs
Q1: What is the power requirement for the Schneider 140DDI67300 module?
A1: The module operates at 24 VDC with an input current of 6.3 mA per channel.
Q2: Can the 140DDI67300 be used with other PLC brands besides Schneider?
A2: No, the 140DDI67300 is specifically designed for Schneider’s Modicon Quantum series and requires the compatible backplane and CPU modules.
Q3: How is troubleshooting performed on the 140DDI67300?
A3: Diagnostic LEDs on the front panel display input status and fault conditions, aiding in quick identification and troubleshooting.
Q4: What is the isolation voltage rating of the 140DDI67300?
A4: The module offers an isolation rating of 1780 Vrms between channels and the system bus.
Q5: How often should maintenance be performed on this module?
A5: It is recommended to inspect the module every six months for dust accumulation, secure wiring, and proper operation.
Q6: What software is required to configure the 140DDI67300?
A6: Unity Pro or EcoStruxure Control Expert software is used for programming and configuration of the module.