Schneider Electric 140DAI74000 Product Documentation
Product Introduction
The Schneider Electric 140DAI74000 is a high-performance analog input module from the Modicon Quantum series. It is designed for industrial automation applications, providing precise analog signal acquisition for process control and monitoring. This module supports multiple input types, including voltage and current signals, making it versatile for various industrial environments.
The 140DAI74000 is known for its reliability, accuracy, and seamless integration with Schneider Electric’s automation systems. It is commonly used in industries such as manufacturing, energy, water treatment, and oil & gas.
Product Advantages
-
High Accuracy – Delivers precise analog signal conversion with minimal error.
-
Wide Input Range – Supports multiple signal types (voltage and current).
-
Robust Design – Built for harsh industrial environments with high immunity to electrical noise.
-
Easy Integration – Compatible with Modicon Quantum PLCs and other Schneider automation products.
-
Hot-Swappable – Allows for module replacement without shutting down the entire system.
-
Diagnostic Features – Provides real-time monitoring and fault detection.
Technical Specifications
Parameter | Specification |
---|---|
Product Code | 140DAI74000 |
Type | Analog Input Module |
Input Channels | 8 channels |
Input Signal Range | 0-10V, ±10V, 0-20mA, 4-20mA |
Resolution | 16-bit |
Accuracy | ±0.1% of full scale |
Isolation | 1500V AC between channels and bus |
Power Supply | 24V DC (19.2V – 30V) |
Power Consumption | 5W max |
Dimensions | 103.9 × 40.3 × 250 mm |
Weight | 0.35 kg |
Operating Temp. | -20°C to +70°C |
Storage Temp. | -40°C to +85°C |
Humidity | 5% to 95% non-condensing |
Certifications | CE, UL, IEC, ATEX (optional) |
Applications
-
Process Control – Monitoring pressure, temperature, and flow rates.
-
Energy Management – Power consumption tracking in industrial plants.
-
Water & Wastewater – Level and pH monitoring.
-
Oil & Gas – Remote sensor data acquisition.
-
Manufacturing Automation – Feedback control for machinery.
Compatible Products
-
PLCs: Modicon Quantum 140CPU65150, 140CPU67160
-
Power Supplies: 140CPS11100, 140CPS21400
-
Communication Modules: 140NOE77101, 140CRP93200
-
Backplane: 140XBP01600, 140XBP01000
Installation Guide
-
Power Off – Ensure the system is powered down before installation.
-
Mounting – Insert the module into an available slot on the Quantum rack.
-
Wiring – Connect analog sensors using shielded cables to minimize noise interference.
-
Configuration – Use Unity Pro software to set input ranges and scaling.
-
Testing – Verify signal accuracy before full operation.
Recommended Similar Models (Same Series)
Model | Type | Channels | Input Range | Resolution | Dimensions (mm) | Weight (kg) | Voltage |
---|---|---|---|---|---|---|---|
140DAI75300 | Analog Input | 16 | 0-10V, 4-20mA | 16-bit | 45 x 126 x 117 | 0.6 | 24V DC |
140DAI54200 | Thermocouple Input | 8 | J, K, T, E, R, S | 16-bit | 45 x 126 x 117 | 0.5 | 24V DC |
140DAI34000 | RTD Input | 8 | PT100, PT1000 | 16-bit | 45 x 126 x 117 | 0.5 | 24V DC |
140DDO84300 | Digital Output | 32 | 24V DC | – | 45 x 126 x 117 | 0.5 | 24V DC |
140DDI84300 | Digital Input | 32 | 24V DC | – | 45 x 126 x 117 | 0.5 | 24V DC |
140AVO03000 | Analog Output | 8 | 0-10V, 4-20mA | 16-bit | 45 x 126 x 117 | 0.6 | 24V DC |
Top 8 Popular Schneider Electric Models
Model | Type | Key Features | Dimensions (mm) | Weight (kg) | Voltage |
---|---|---|---|---|---|
TeSys D Green | Contactor | Energy-efficient, 9-32A rating | 90 x 45 x 78 | 0.3 | 24-690V AC |
Altivar 320 | Variable Speed Drive | 0.75-75kW, Ethernet/IP support | Multiple sizes | 1.5-15 | 380-480V AC |
Modicon M221 | PLC | Compact, 24 I/O, embedded Ethernet | 90 x 80 x 59 | 0.5 | 24V DC |
Harmony XB5 | Push Button | Modular, illuminated, IP65 | 22 x 22 x 55 | 0.1 | 24V DC |
PowerLogic PM800 | Energy Meter | MID certified, 0.5S class accuracy | 96 x 96 x 70 | 0.6 | 110-480V AC |
Telemecanique LC1D | Contactor | 9-150A, high durability | 45 x 78 x 90 | 0.4 | 110-440V AC |
Magelis HMI | Touch Panel | 7″-15″, Ethernet, rugged design | 200 x 150 x 50 | 1.2 | 24V DC |
Compact NSX | Circuit Breaker | 16-630A, Micrologic protection | 90 x 70 x 80 | 1.0 | 220-690V AC |
Frequently Asked Questions (FAQ)
Q1: What is the maximum sampling rate of the 140DAI74000?
A1: The module supports a sampling rate of up to 10ms per channel.
Q2: Can this module be used in hazardous environments?
A2: Yes, with optional ATEX certification, it can be used in explosive atmospheres.
Q3: Is calibration required before installation?
A3: Factory calibration is sufficient, but periodic recalibration is recommended for critical applications.
Q4: What is the lifespan of the 140DAI74000?
A4: Under normal conditions, the module has a lifespan of over 10 years.
Q5: Can I mix voltage and current inputs on the same module?
A5: No, all channels must be configured for the same input type.
Q6: What software is needed for configuration?
A6: Schneider Electric’s Unity Pro software is required for setup and diagnostics.
Schneider 140DAI74000 Discrete output modules