Yokogawa ALR121-SE1 Product Overview
The Yokogawa ALR121-SE1 is a premium relay output module developed for reliable operation within Yokogawa’s control system platforms. Specifically designed for integration with industrial automation systems, the ALR121-SE1 ensures efficient signal transmission and robust mechanical switching capabilities. This model is engineered with advanced contact materials and precise control logic, providing high endurance for demanding applications, including process industries, energy management, and manufacturing automation.
The module is highly compatible with the Yokogawa CENTUM VP and ProSafe-RS systems, ensuring seamless integration and offering long-term operational stability. Its compact design, easy installation, and high response speed make it an essential component for systems requiring accurate relay output performance.
Advantages of Yokogawa ALR121-SE1
-
High Reliability: Manufactured with premium-grade components ensuring extended operational life even in harsh industrial environments.
-
Fast Response Time: Optimized for rapid switching to accommodate real-time control applications.
-
Compact Design: Space-saving structure ideal for installation in dense control cabinets.
-
Wide Compatibility: Fully compatible with Yokogawa’s DCS and SIS systems such as CENTUM VP and ProSafe-RS.
-
Energy Efficiency: Designed for minimal power consumption, contributing to overall system energy savings.
-
Easy Maintenance: Modular design enables simple replacement and reduces system downtime.
Technical Specifications of Yokogawa ALR121-SE1
Parameter | Specification |
---|---|
Model Number | ALR121-SE1 |
Dimensions | 126.7 × 32.8 × 130 mm |
Weight | 0.3 kg |
Power Supply Voltage | 24 VDC (Nominal) |
Operating Voltage Range | 18 VDC to 32 VDC |
Relay Output Type | SPST-NO (Single Pole Single Throw – Normally Open) |
Contact Rating | 30 VDC / 2 A resistive load |
Switching Speed | ≤ 10 ms |
Insulation Resistance | > 100 MΩ at 500 VDC |
Dielectric Strength | 1000 VAC for 1 minute between contact and coil |
Mounting | DIN Rail Mounting |
Operating Temperature | 0°C to +55°C |
Storage Temperature | -20°C to +70°C |
Vibration Resistance | 5 Hz to 10 Hz: 3.5 mm amplitude, 10 Hz to 150 Hz: 9.8 m/s² acceleration |
Shock Resistance | 147 m/s² (15G) for 11 ms |
Certifications | CE Marked, RoHS Compliant |
Applications of Yokogawa ALR121-SE1
-
Distributed Control Systems (DCS): Essential for discrete output management within Yokogawa’s CENTUM VP platforms.
-
Safety Instrumented Systems (SIS): Utilized within ProSafe-RS architectures for fail-safe relay operations.
-
Manufacturing Automation: Supports various relay control functions in automotive, semiconductor, and electronics manufacturing plants.
-
Energy Management: Employed in energy production and distribution systems for reliable switching control.
-
Oil & Gas Industry: Integral for remote I/O control in upstream and downstream processes.
-
Water Treatment Plants: Controls valve operations and pump systems requiring high reliability and durability.
Compatible Models for ALR121-SE1
-
AAI141-S00 (Analog Input Module)
-
AAI543-S00 (Analog Output Module)
-
ADV151-P00 (Digital Input Module)
-
ADV551-P00 (Digital Output Module)
-
SAI533-S03 (Safety Analog Input Module)
-
SDO513-S03 (Safety Digital Output Module)
-
ALR111-S10 (Relay Output Module)
Installation Instructions for Yokogawa ALR121-SE1
-
Pre-Installation Check:
Ensure that the module matches the control system specifications and verify that the environment meets operating conditions. -
Mounting:
Mount the ALR121-SE1 securely on a DIN rail. Allow adequate space around the module for ventilation. -
Wiring:
Connect the relay outputs and power supply according to the wiring diagrams provided in the installation manual. Use appropriately rated cables. -
Powering Up:
After wiring, power on the system and verify correct module recognition by the host controller. -
Testing:
Perform a functional check to ensure relay outputs are switching correctly according to control signals. -
Maintenance Tips:
Regularly inspect connections and clean any dust accumulation to maintain optimum performance.
Recommended 6 Related or Same Series Models
Model | Description | Dimensions (W x H x D) | Weight | Voltage |
---|---|---|---|---|
ALR111-S10 | Relay Output Module | 27 mm × 130 mm × 160 mm | 250 g | 24 VDC |
ALR131-S00 | High Capacity Relay Output Module | 27 mm × 130 mm × 160 mm | 260 g | 24 VDC |
ADV551-P00 | Digital Output Module | 27 mm × 130 mm × 160 mm | 240 g | 24 VDC |
ADV151-P00 | Digital Input Module | 27 mm × 130 mm × 160 mm | 240 g | 24 VDC |
ALR121-S00 | Standard Relay Output Module | 27 mm × 130 mm × 160 mm | 250 g | 24 VDC |
AAI141-S00 | Analog Input Module | 27 mm × 130 mm × 160 mm | 230 g | 24 VDC |
8 Popular Yokogawa Models Recommendation
Model | Description | Dimensions (W x H x D) | Weight | Voltage |
---|---|---|---|---|
CP451-50 | Processor Module | 40 mm × 130 mm × 160 mm | 280 g | 24 VDC |
NFAI143-S50 | Analog Input Module | 27 mm × 130 mm × 160 mm | 250 g | 24 VDC |
F3LE11-0T | Digital Output Module | 40 mm × 130 mm × 160 mm | 280 g | 24 VDC |
NFDV161-P50 | Digital Output Module | 27 mm × 130 mm × 160 mm | 240 g | 24 VDC |
AAI143-H50 | High Performance Analog Input Module | 27 mm × 130 mm × 160 mm | 250 g | 24 VDC |
ADV551-P03 | Digital Output Module | 27 mm × 130 mm × 160 mm | 240 g | 24 VDC |
SAI533-S03 | Safety Analog Input Module | 27 mm × 130 mm × 160 mm | 250 g | 24 VDC |
SDO513-S03 | Safety Digital Output Module | 27 mm × 130 mm × 160 mm | 240 g | 24 VDC |
Yokogawa ALR121-SE1 FAQs (Q&A Format)
Q1: What is the primary function of the Yokogawa ALR121-SE1?
A1: The ALR121-SE1 serves as a relay output module that facilitates reliable switching operations within industrial control systems, ensuring safe and accurate control of external devices.
Q2: Can the ALR121-SE1 operate in extreme temperatures?
A2: Yes, the ALR121-SE1 is designed to operate reliably between 0°C and +55°C and can be stored between -20°C and +70°C.
Q3: Which control systems are compatible with ALR121-SE1?
A3: The ALR121-SE1 is compatible with Yokogawa’s CENTUM VP Distributed Control System and ProSafe-RS Safety Instrumented System.
Q4: How is the ALR121-SE1 mounted within a control panel?
A4: It is mounted on a standard DIN rail, allowing for easy installation and maintenance in control cabinets.
Q5: What are the maintenance requirements for ALR121-SE1?
A5: Periodic inspection for wiring integrity, cleaning of dust or debris, and functional testing during scheduled maintenance intervals are recommended.
Q6: Does the ALR121-SE1 have safety certifications?
A6: Yes, the ALR121-SE1 is CE marked and RoHS compliant, ensuring it meets international safety and environmental standards.