Yokogawa ADM52-2 S4 Technical Product Overview
Product Introduction
The Yokogawa ADM52-2 S4 is a high-performance analog input module designed for industrial automation and process control systems. As part of Yokogawa’s advanced DCS (Distributed Control System) architecture, this module offers exceptional signal accuracy, robust design, and seamless integration with other Yokogawa system components.
This model is engineered to interface analog signals such as temperature, pressure, flow, or level transmitters to the DCS for monitoring and control purposes. With multi-channel capability, galvanic isolation, and signal filtering, the ADM52-2 S4 enhances the reliability and accuracy of process data acquisition in mission-critical applications.
The module meets the demands of various industries including oil and gas, petrochemical, power generation, water treatment, and pharmaceuticals.
Product Advantages
-
High Precision Analog Signal Acquisition
The ADM52-2 S4 ensures accurate and stable analog input reading with minimal signal noise and drift over time. -
Wide Input Signal Compatibility
Supports a wide range of analog input signals including 4–20 mA, 1–5 V, and thermocouples, making it highly adaptable. -
Built-in Isolation and Protection
Galvanic isolation between channels and internal protection circuits reduce the risk of signal interference and improve reliability. -
Compact and Modular Design
Saves panel space while enabling easy installation and maintenance. -
Real-Time Diagnostics
Integrated health monitoring features provide real-time alerts on channel status and module performance. -
Full Integration with Yokogawa Control Systems
Seamlessly compatible with Yokogawa CENTUM VP, ProSafe-RS, and other related platforms.
Technical Specifications
Parameter | Specification |
---|---|
Model | ADM52-2 S4 |
Input Channels | 16 analog input channels |
Input Signal Types | 4–20 mA, 1–5 V, ±10 V, Thermocouple, RTD |
Accuracy | ±0.1% of span |
Resolution | 16-bit A/D converter |
Isolation | Channel-to-channel and channel-to-ground |
Response Time | < 100 ms (typical) |
Power Supply Voltage | 24 VDC nominal (20.4–28.8 VDC range) |
Power Consumption | 3.5 W (typical) |
Operating Temperature | 0 to 60°C |
Storage Temperature | -20 to +70°C |
Relative Humidity | 5–95% RH (non-condensing) |
Mounting Method | DIN rail or panel mount |
Dimensions | 130 × 100 × 30 mm |
Weight | 1.5 kg |
Certifications | CE, CSA, ATEX, IECEx |
Applications
-
Oil & Gas: Real-time monitoring of pressure, temperature, and flow from remote sensors in upstream and downstream processes.
-
Chemical & Petrochemical: Control and feedback systems for maintaining optimal chemical process conditions.
-
Power Generation: Data acquisition for turbine, generator, and boiler instrumentation.
-
Pharmaceutical: Process validation and temperature monitoring in cleanroom environments.
-
Water and Wastewater Treatment: Monitoring pH, turbidity, and flow rates across treatment units.
-
Food & Beverage: Precision temperature and flow control in processing lines.
Compatible Models
The ADM52-2 S4 is designed to work seamlessly with the following Yokogawa modules and systems:
-
CPU Modules: AFV30D, AFP34D
-
Base Units: ABV10D, ABP13D
-
I/O Modules: ADV151, ADV551, ADV561
-
Power Supply Modules: PW482-10, PW702
-
Communication Modules: AAI143-H50, AAI543-H00
-
System Controllers: Yokogawa CENTUM VP, ProSafe-RS
Installation Instructions
-
Pre-Installation Check
Verify model number, power requirements, and ensure the module is free from physical damage. Ensure all wiring and panel requirements comply with safety regulations. -
Mounting the Module
Mount the ADM52-2 S4 securely to a DIN rail or panel surface using appropriate screws or rail clips. Leave at least 50 mm clearance on all sides for heat dissipation. -
Wiring and Terminal Connections
Connect analog input wires to designated terminals. Follow Yokogawa wiring diagram and maintain polarity. Use shielded cables for noise immunity. -
Power Supply Connection
Connect a stable 24 VDC supply with proper grounding. Use surge protection where necessary. -
System Integration
Configure the module via Yokogawa’s engineering tools. Set channel types, ranges, and scaling parameters. -
Testing and Commissioning
Perform a full functional test of each input channel. Monitor signal response and verify correct integration with the control system.
6 Related or Same-Series Models
Model | Description | Input Type | Channels | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
ADM52-1 S4 | Analog input module, basic version | 4–20 mA | 8 | 24 VDC | 120 x 130 x 60 | 500 g |
ADM12-2 | Analog input, high-speed scan | 1–5 V | 16 | 24 VDC | 120 x 130 x 60 | 530 g |
AAI141-H50 | High-density analog input module | RTD | 16 | 24 VDC | 120 x 130 x 60 | 560 g |
AAI543-H00 | Universal input with HART support | 4–20 mA, TC | 8 | 24 VDC | 120 x 130 x 65 | 580 g |
ADV551 | Multipoint voltage input | ±10 V | 16 | 24 VDC | 120 x 130 x 60 | 540 g |
ADM92-4 | Analog mixed-signal input | Current & Voltage | 16 | 24 VDC | 120 x 130 x 60 | 560 g |
8 Popular Yokogawa Models
Model | Description | Function | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
CP451-50 | CPU module for field control station | System Controller | 24 VDC | 130 x 140 x 65 | 600 g |
AAI143-H50 | Analog input module with HART | Analog Input | 24 VDC | 120 x 130 x 60 | 550 g |
ADV151 | Discrete input module | Digital Input | 24 VDC | 120 x 130 x 50 | 470 g |
AAI543-H00 | Analog input module | Analog Input | 24 VDC | 120 x 130 x 65 | 580 g |
PW482-10 | Power supply module | Power Supply | 24 VDC | 130 x 160 x 70 | 680 g |
NFAI143-S50 | Field analog input module | Analog Input | 24 VDC | 130 x 140 x 60 | 540 g |
NFDV161-P50 | Digital output module | Digital Output | 24 VDC | 130 x 140 x 60 | 550 g |
F3LE11-0T | Expansion I/O module for FA-M3 | Logic Input | 24 VDC | 100 x 110 x 45 | 400 g |
FAQs (Frequently Asked Questions)
Q1: What types of analog signals does the ADM52-2 S4 support?
A1: The ADM52-2 S4 supports various analog inputs including 4–20 mA, 1–5 V, ±10 V, thermocouples, and RTDs, making it versatile for most industrial applications.
Q2: Can the ADM52-2 S4 be installed in hazardous environments?
A2: Yes, the ADM52-2 S4 is certified for use in hazardous areas with ATEX and IECEx compliance, provided proper enclosure and installation practices are followed.
Q3: Is this module compatible with Yokogawa CENTUM VP systems?
A3: Absolutely. The ADM52-2 S4 is fully compatible with CENTUM VP and can be configured using Yokogawa’s engineering tools.
Q4: How many channels does the ADM52-2 S4 offer?
A4: It offers 16 analog input channels, each with isolated signal paths for reliable and accurate measurement.
Q5: What are the physical dimensions and weight of the module?
A5: The dimensions are 120 mm x 130 mm x 60 mm, and the weight is approximately 550 grams.
Q6: How is maintenance performed on this module?
A6: Maintenance involves checking signal integrity, ensuring clean and secure terminal connections, and running diagnostic tests via the DCS interface. The module is designed for easy replacement without disrupting system operation.