Yokogawa AAM50-S1 Product Overview
The Yokogawa AAM50-S1 is a high-performance analog input module designed for use in distributed control systems (DCS) such as Yokogawa’s CENTUM series. Engineered with precision and reliability in mind, the AAM50-S1 facilitates accurate analog signal processing, making it ideal for a wide array of industrial automation and process control applications. This model offers high-resolution analog data acquisition, multiple input channels, and seamless integration with Yokogawa’s advanced control platforms.
With its robust build, advanced diagnostic capabilities, and user-friendly configuration, the AAM50-S1 sets a high standard for performance, reliability, and interoperability within industrial environments.
Product Advantages
-
High Accuracy & Resolution: Offers superior analog signal processing with minimal error margins, supporting accurate control and monitoring.
-
Wide Compatibility: Fully compatible with CENTUM CS 3000 and CENTUM VP systems, enhancing system flexibility.
-
Channel Isolation: Ensures electrical isolation between channels, reducing interference and improving safety.
-
Hot Swap Capability: Supports online replacement without system downtime, facilitating continuous operation.
-
Compact Design: Saves panel space while maintaining full functionality, ideal for modern industrial setups.
-
Advanced Diagnostics: Built-in self-diagnostics for real-time fault detection and maintenance support.
Technical Specifications
Parameter | Specification |
---|---|
Model Number | AAM50-S1 |
Input Type | Analog (Voltage/Current) |
Number of Channels | 8 Channels |
Signal Range | 0–10 VDC, 4–20 mA |
Resolution | 16-bit |
Input Isolation | Channel-to-channel and channel-to-GND |
Power Supply Voltage | 24 VDC |
Dimensions | 42.9 × 130 × 146.8 mm |
Weight | 0.10 kg |
Operating Temperature | 0 to 50°C |
Storage Temperature | -20 to 70°C |
Humidity | 5% to 95% RH (non-condensing) |
Mounting | DIN rail or panel mount |
Certifications | CE, CSA, UL |
Applications
The Yokogawa AAM50-S1 is widely used in a variety of industries, including:
-
Oil & Gas: For monitoring analog sensor data such as pressure and flow in pipelines.
-
Chemical Processing: Ensures precision in temperature and chemical level control systems.
-
Water Treatment Plants: For continuous monitoring of flow rates, pH, and conductivity.
-
Power Generation: Applied in steam and gas turbine instrumentation.
-
Pharmaceutical Manufacturing: Used for controlling temperature, pressure, and fluid flow.
-
Food and Beverage: Enables reliable analog signal input from field devices in automated processing lines.
Compatible Models
The AAM50-S1 is designed to work seamlessly with the following Yokogawa system components:
-
AFV10D – Field control unit base
-
CP451-10 – Processor module
-
PW482-10 – Power supply module
-
AMM12C – Analog input module (extended channel version)
-
AAT145-S00 – Thermocouple input module
-
ADV551-P50 – Digital output module
These components together ensure the integrity and performance of a complete DCS infrastructure.
Installation Instructions
-
Power Down the System: Ensure the main control system is powered down before installation to avoid electric shock or component damage.
-
Mount the Module: Secure the AAM50-S1 module onto a DIN rail or panel using the provided mounting brackets. Ensure it’s properly grounded.
-
Connect I/O Wiring: Use shielded cables for input signal wiring. Connect signal wires to the designated terminal block, ensuring correct polarity and channel assignments.
-
Configure Channels: Via the engineering tool (such as Yokogawa’s Control Drawing Tool), configure each channel with the appropriate signal type and range.
-
Verify Settings: Cross-check all channel configurations and wiring before powering up.
-
System Integration: Load module configuration into the control system and verify communication through the HMI or engineering station.
-
Perform Testing: Conduct loop testing and calibration for each input channel to ensure accuracy.
-
Enable Operation: Activate the control loop and monitor module performance during the initial operation phase.
Related Models (Same or Similar Series)
Model | Description | Channels | Input Type | Dimensions (mm) | Weight |
---|---|---|---|---|---|
AAM11 | Analog Input Module (Basic) | 8 | Voltage/Current | 27 x 130 x 160 | 0.35 kg |
AAM51-S1 | High-Density Analog Input Module | 16 | Voltage/Current | 27 x 130 x 160 | 0.38 kg |
AMM12C | Multipoint Analog Input Module | 16 | Current | 27 x 130 x 160 | 0.40 kg |
AAT145-S00 | Thermocouple Input Module | 8 | TC (T, K, J types) | 27 x 130 x 160 | 0.36 kg |
AAI543-S00 | Isolated Analog Input Module | 8 | Voltage/Current | 27 x 130 x 160 | 0.35 kg |
AAI141-H50 | Analog Input Module for High-Speed DCS | 8 | Current | 27 x 130 x 160 | 0.34 kg |
8 Popular Yokogawa Models
Model | Description | Type | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
CP451-50 | Control Processor | CPU Module | 24 VDC | 50 x 150 x 200 | 0.70 kg |
PW482-10 | Power Supply Module | Power Supply | 24 VDC | 40 x 130 x 160 | 0.45 kg |
ADV151-P03 | Digital Input Module | Digital Input | 24 VDC | 27 x 130 x 160 | 0.34 kg |
ADV551-P50 | Digital Output Module | Digital Output | 24 VDC | 27 x 130 x 160 | 0.35 kg |
AAI141-H00 | Analog Input Module | Analog Input | 24 VDC | 27 x 130 x 160 | 0.34 kg |
AAI543-S00 | Analog Input Isolated Module | Analog Input | 24 VDC | 27 x 130 x 160 | 0.35 kg |
AMN11 | Analog Multiplexer | Multiplexer Module | 24 VDC | 27 x 130 x 160 | 0.36 kg |
AFF50D | Field Control Base Module | Base Frame | 24 VDC | 100 x 130 x 160 | 0.80 kg |
Frequently Asked Questions (FAQs)
Q1: What signal types does the AAM50-S1 support?
A1: The AAM50-S1 supports both voltage (0–10 V) and current (4–20 mA) analog signals, making it suitable for a wide range of process input devices.
Q2: Can I replace the AAM50-S1 module without shutting down the entire system?
A2: Yes, the AAM50-S1 supports hot-swapping, allowing for module replacement while the system is online, provided safety precautions are followed.
Q3: How many channels are available on the AAM50-S1?
A3: This model offers 8 fully isolated analog input channels.
Q4: Is this module compatible with CENTUM VP systems?
A4: Yes, it is fully compatible with Yokogawa’s CENTUM VP and CENTUM CS 3000 systems.
Q5: What is the main benefit of channel-to-channel isolation?
A5: Channel-to-channel isolation prevents signal interference and enhances data accuracy and system safety, particularly in high-noise industrial environments.
Q6: Does the module require any calibration after installation?
A6: Calibration is recommended after installation to ensure accurate readings. Yokogawa’s engineering tools facilitate easy calibration and diagnostics.
Yokogawa AAM50-S1 Current and voltage output modules
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |