Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Introduction – Yokogawa AAM21-S2
The Yokogawa AAM21-S2 is a high-performance Analog Input Module designed for use with the CENTUM CS 3000 and CENTUM VP Distributed Control Systems (DCS). Developed with precision and reliability in mind, this module is tailored for demanding industrial automation applications that require accurate analog signal acquisition and processing. With support for various input types and signal conditioning features, the AAM21-S2 serves as a vital component in Yokogawa’s control ecosystem, enhancing real-time data acquisition and control loop performance.
This module is widely used in industries such as petrochemical, power generation, pharmaceuticals, and manufacturing, offering stable operation in critical process environments. The AAM21-S2 meets stringent safety, interoperability, and durability standards, ensuring maximum uptime and minimal maintenance requirements.
Product Advantages
-
High Signal Accuracy
The AAM21-S2 provides precise analog input readings with minimal drift, ensuring accurate process control and monitoring. -
Multi-Signal Compatibility
Supports a wide range of analog signals, including voltage and current types, accommodating various field instruments. -
Noise-Resistant Design
Engineered with robust shielding and grounding methods to reduce susceptibility to electromagnetic interference (EMI). -
Hot Swappable Capability
Enables module replacement without shutting down the entire system, improving maintainability and minimizing operational disruption. -
Diagnostics and Monitoring
Integrated diagnostics allow for real-time monitoring of module health and input status, reducing troubleshooting time. -
Integration with Yokogawa DCS
Seamlessly integrates with CENTUM series control systems, enhancing system responsiveness and operational synergy.
Technical Specifications
Parameter | Specification |
---|---|
Model Number | AAM21-S2 |
Input Type | Analog (Voltage / Current) |
Number of Channels | 16 Channels |
Signal Range | 4–20 mA, 0–10 V, 1–5 V (Configurable) |
Accuracy | ±0.1% of F.S. |
Resolution | 16-bit A/D Conversion |
Input Impedance | > 1 MΩ (Voltage), 250Ω (Current) |
Power Supply Voltage | 24 V DC (±10%) |
Power Consumption | Approx. 3.2 W |
Operating Temperature | 0°C to +50°C |
Storage Temperature | -20°C to +70°C |
Humidity Range | 5% to 95% RH (non-condensing) |
Dimensions | 42.9 × 130 × 146.8 mm |
Weight | 0.10 kg |
Mounting Method | Mounted on Base Plate |
Certifications | CE, CSA, RoHS Compliant |
Applications
-
Oil & Gas Refineries
For monitoring analog signals from pressure transmitters, temperature sensors, and flow meters. -
Chemical Processing Plants
Used to capture analog signals for various control loops in reactor and distillation systems. -
Power Generation Facilities
Gathers input from turbines, generators, and auxiliary systems for precise energy management. -
Pharmaceutical Manufacturing
Ensures compliance with GMP through accurate environmental monitoring and process validation. -
Water & Wastewater Treatment
Processes data from field devices like pH sensors, level sensors, and flow instruments for automated plant control.
Compatible Models
-
Yokogawa AAI141-H00 – Analog input module, compatible with same baseplate and signal processing units.
-
Yokogawa AAI143-S00 – Offers redundancy features for critical applications.
-
Yokogawa ADV151-P03 – Digital I/O module for applications that integrate both analog and digital signals.
-
Yokogawa AAB841-S00 – Terminal block assembly used with the AAM21-S2.
-
Yokogawa ANB10D-420 – Node interface unit for segment-based system architecture.
-
Yokogawa PW482-S01 – Power supply module suitable for stable power input to AAM modules.
Installation Instructions
-
Power Down System (If Not Hot Swapping)
Ensure the system is powered down unless performing a hot-swap operation. -
Baseplate Preparation
Mount the AAM21-S2 onto a compatible Yokogawa baseplate. Verify that the terminal block is clean and properly installed. -
Wiring Connections
Connect field analog input wiring to the designated terminal block. Use shielded cables for better noise immunity. -
Check Polarity and Signal Types
Ensure current and voltage signal types are correctly configured to avoid module damage. -
System Configuration
In the CENTUM engineering tool, assign the module to its designated I/O slot and configure signal scaling parameters. -
Power-Up and Validation
Power on the system and validate the inputs via diagnostics tools. Check all channel values for accuracy.
6 Related Models
Model | Type | Channels | Signal Type | Voltage | Size (mm) | Weight |
---|---|---|---|---|---|---|
AAI141-H00 | Analog Input Module | 16 | 4–20 mA, 1–5 V | 24 V DC | 27.2 × 130 × 176 | 0.5 kg |
AAI143-S00 | Analog Input Module | 8 (Redundant) | 4–20 mA, 0–10 V | 24 V DC | 27.2 × 130 × 176 | 0.55 kg |
ADV551-P03 | Digital Input Module | 16 | Digital 24 V DC | 24 V DC | 27.2 × 130 × 176 | 0.45 kg |
AAM50-S1 | Multiplexer Module | 32 | Mixed Analog Input | 24 V DC | 45 × 130 × 200 | 0.6 kg |
AAI135-S00 | Isolated AI Module | 16 | 4–20 mA Isolated | 24 V DC | 27.2 × 130 × 176 | 0.52 kg |
AAV144-H53 | RTD Input Module | 8 | RTD, Thermocouple | 24 V DC | 27.2 × 130 × 176 | 0.48 kg |
8 Popular Yokogawa Models
Model | Type | Channels | Function | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
AAI841-H00 | Analog Input Module | 8 | High-speed analog input | 24 V DC | 27.2 × 130 × 176 | 0.5 kg |
AAI143-S00 | Analog Input Module | 8 | Redundant signal processing | 24 V DC | 27.2 × 130 × 176 | 0.55 kg |
ADV551-P03 | Digital Input Module | 16 | Digital ON/OFF acquisition | 24 V DC | 27.2 × 130 × 176 | 0.45 kg |
CP451-50 | Processor Module | – | CPU for control system | 24 V DC | 70 × 150 × 180 | 1.2 kg |
PW482-S01 | Power Supply Module | – | Stable power for modules | 24 V DC | 40 × 150 × 160 | 0.75 kg |
AAI835-H00 | Analog Input Module | 16 | Fast sampling input | 24 V DC | 27.2 × 130 × 176 | 0.53 kg |
SAI533-H00 | Serial Interface Unit | 4 Ports | RS-485 Communication | 24 V DC | 30 × 130 × 180 | 0.6 kg |
NFAI143-S50 | AI Safety Module | 8 | SIL-certified input module | 24 V DC | 27.2 × 130 × 176 | 0.56 kg |
Frequently Asked Questions (FAQ)
Q1: What type of signals does the AAM21-S2 support?
A1: The AAM21-S2 supports a range of analog input signals, including 4–20 mA, 0–10 V, and 1–5 V, making it compatible with most industrial sensors.
Q2: Can the AAM21-S2 be hot-swapped without shutting down the DCS?
A2: Yes, the module is hot-swappable, allowing maintenance or replacement while the system is operational.
Q3: How many channels are available on the AAM21-S2 module?
A3: The AAM21-S2 features 16 independent analog input channels.
Q4: What is the resolution of the analog-to-digital conversion?
A4: The AAM21-S2 offers 16-bit resolution for high precision signal processing.
Q5: Is this module compatible with CENTUM VP systems?
A5: Yes, it integrates seamlessly with both CENTUM CS 3000 and CENTUM VP systems.
Q6: What diagnostics features does the module provide?
A6: It provides real-time health status monitoring, input diagnostics, and error reporting via the engineering tool.
Yokogawa AAM21-S2 RTD Input Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |