Yokogawa AAM10-S1 Module Overview
Product Introduction
The Yokogawa AAM10-S1 is a high-performance analog input module designed for use within the Yokogawa CENTUM VP and CS 3000 distributed control systems (DCS). As part of the I/O subsystem architecture, this module plays a critical role in collecting and converting analog signals from field instruments, such as transmitters and sensors, into digital values for further processing and control.
Designed with precision, the AAM10-S1 ensures high-speed data acquisition, excellent noise immunity, and reliable operation in demanding industrial environments. It provides high-density channel configurations while maintaining excellent signal accuracy and stability, making it suitable for use in process automation systems across a wide range of industries.
Product Advantages
-
High Accuracy and Stability: Designed for precise analog input conversion with excellent long-term stability and low drift.
-
Noise Immunity: Features strong resistance against electromagnetic interference (EMI), ensuring accurate signal acquisition even in harsh environments.
-
Compact Design: High-density channel architecture allows more I/O per module, reducing cabinet space requirements and overall system footprint.
-
Hot-Swap Capability: Enables module replacement without shutting down the system, enhancing uptime and operational continuity.
-
Diagnostics and Health Monitoring: Built-in diagnostic functions for channel integrity and wiring conditions, aiding in preventive maintenance.
-
Seamless Integration: Natively integrates with Yokogawa’s CENTUM VP and CS 3000 DCS, supporting fast configuration and commissioning.
Technical Specifications
Parameter | Details |
---|---|
Model Number | AAM10-S1 |
Type | Analog Input Module |
Number of Channels | 16 Channels (Single-Ended) |
Signal Type | 4-20 mA, 1-5 V, 0-10 V (Configurable per channel) |
Resolution | 16-bit |
Conversion Method | Successive Approximation ADC |
Sampling Time | 100 ms/channel |
Isolation | Channel-to-channel and channel-to-ground |
Voltage Range | 18 – 32 VDC (Nominal: 24 VDC) |
Power Consumption | Approx. 4.5 W |
Operating Temperature | 0°C to +60°C |
Storage Temperature | -20°C to +70°C |
Dimensions | 42.9 × 130 × 146.8 mm |
Weight | 0.10 kg |
Mounting | DIN Rail or Panel Mount |
Certification | CE, RoHS, CSA, ATEX compliant |
Applications
-
Oil & Gas: Analog signal acquisition from pressure, temperature, and flow transmitters in upstream and downstream applications.
-
Chemical and Petrochemical: Process monitoring and control in refineries and chemical reactors.
-
Power Generation: Integration into boiler management systems and turbine control.
-
Pharmaceutical: Environmental and process parameter monitoring in cleanrooms and production lines.
-
Water & Wastewater: Monitoring flow, pressure, and quality in treatment plants.
-
Pulp & Paper: Integration into process control loops for pressure, temperature, and chemical dosing control.
Compatible Models
The AAM10-S1 is compatible with the following Yokogawa system components and modules:
-
Field Control Station (FCS) in CENTUM VP and CS 3000
-
ALR10: Baseplate for I/O modules
-
PWC10: Power wiring terminal block
-
ATD5A-00: Terminal Board for Analog Input
-
VJ Series Isolators: For signal isolation
-
PRM (Plant Resource Manager) for device management and diagnostics
Installation Instructions
-
Power Down: If not using hot-swap functionality, power down the control system.
-
Mounting: Install the AAM10-S1 module onto the appropriate baseplate (ALR10) securely using DIN rail or panel mounting.
-
Wiring: Connect analog field signals to the terminal block (ATD5A-00) associated with the AAM10-S1. Ensure all wiring complies with recommended specifications.
-
Configuration: Use the engineering tool (e.g., CENTUM VP’s HIS) to define channel types, ranges, and tag assignments.
-
Verification: Perform loop checks and diagnostics to verify correct wiring and signal integrity.
-
Commissioning: Activate the module within the system and monitor input values for expected performance.
6 Related or Same Series Models
Model | Description | Channels | Signal Type | Dimensions (mm) | Weight |
---|---|---|---|---|---|
AAM11-S1 | Analog Input Module (Redundant Input) | 8 | 4-20 mA | 130 x 27.9 x 180 | 0.4 kg |
AAM50-S1 | Analog Output Module | 16 | 4-20 mA | 130 x 27.9 x 180 | 0.45 kg |
AAI141-H50 | High-Speed Analog Input Module | 16 | 1-5 V, Thermocouple | 130 x 27.9 x 180 | 0.5 kg |
AAI543-H00 | High Density Analog Input, 32 channels | 32 | 4-20 mA | 130 x 50 x 180 | 0.6 kg |
AAI835-H00 | Temperature Input Module (RTD) | 8 | RTD | 130 x 27.9 x 180 | 0.45 kg |
AAM10C | Analog Input Module for Compact Systems | 8 | 4-20 mA | 110 x 22 x 160 | 0.35 kg |
8 Popular Yokogawa Models
Model | Type | Function | Dimensions (mm) | Weight | Voltage |
---|---|---|---|---|---|
AAI141-H50 | Analog Input Module | AI, High-Speed | 130 x 27.9 x 180 | 0.5 kg | 24 VDC |
AAI143-H50 | Analog Input Module | AI, Thermocouple/RTD | 130 x 27.9 x 180 | 0.48 kg | 24 VDC |
AAI543-H00 | Analog Input Module | AI, 32-channel High Density | 130 x 50 x 180 | 0.6 kg | 24 VDC |
AAI835-H00 | Analog Input Module | AI, RTD | 130 x 27.9 x 180 | 0.45 kg | 24 VDC |
AAI841-H00 | Analog Input Module | AI, Isolated Channels | 130 x 27.9 x 180 | 0.5 kg | 24 VDC |
ADV551-P50 | Digital Input Module | DI, Isolated 16-channel | 130 x 27.9 x 180 | 0.4 kg | 24 VDC |
ADO141-S00 | Digital Output Module | DO, 16-channel | 130 x 27.9 x 180 | 0.4 kg | 24 VDC |
CP451-10 | CPU Module | Central Processing Unit | 130 x 50 x 200 | 0.7 kg | 24 VDC |
FAQ (Q&A Format)
Q1: What is the function of the AAM10-S1 module?
A1: The AAM10-S1 module is designed to acquire analog signals from field devices such as pressure, temperature, or flow transmitters and convert them into digital signals for use within a DCS.
Q2: Is the AAM10-S1 suitable for redundant configurations?
A2: The standard AAM10-S1 is not redundant by itself, but Yokogawa offers redundant variants like AAM11-S1 for critical applications.
Q3: How many channels does the AAM10-S1 support?
A3: The module supports up to 16 single-ended analog input channels.
Q4: Can this module support different signal types on each channel?
A4: Yes, each channel can be independently configured to accept different signal types such as 4-20 mA or 1-5 V.
Q5: Is the module hot-swappable?
A5: Yes, the AAM10-S1 supports hot-swapping when used within a fully redundant Yokogawa control system.
Q6: What certifications does the AAM10-S1 carry?
A6: The module is CE marked and complies with international standards including RoHS, CSA, and ATEX for safe industrial use.