Yokogawa AAI835-S50 Analog Input Module
Product Introduction
The Yokogawa AAI835-S50 is a high-performance analog input module designed for use in distributed control systems (DCS), specifically in Yokogawa’s CENTUM VP and ProSafe-RS control platforms. It offers high-speed, high-resolution analog signal acquisition from a wide range of field sensors. Engineered for precision and reliability, this module plays a critical role in enabling accurate process monitoring and control in various industrial environments.
The AAI835-S50 supports 8 input channels, each capable of handling 4 to 20 mA analog signals. It is equipped with advanced diagnostics and signal processing capabilities to ensure smooth integration into complex automation systems.
Product Advantages
-
High Accuracy and Resolution: Delivers precise data acquisition with minimal signal distortion or loss.
-
Multi-channel Capability: Offers 8 independent channels for simultaneous multi-point data collection.
-
Built-in Diagnostics: Integrated self-diagnosis features detect wiring errors, module failure, or sensor faults, improving system reliability.
-
Fast Data Processing: Supports rapid data sampling and transfer to the controller, suitable for time-sensitive applications.
-
Easy Integration: Seamlessly integrates with Yokogawa’s ProSafe-RS and CENTUM VP platforms.
-
Robust Design: Engineered for durability in harsh environments, offering high resistance to vibration and electrical noise.
-
Hot Swap Support: Allows for module replacement without system shutdown, ensuring maximum uptime.
Technical Specifications
Parameter | Description |
---|---|
Model Number | AAI835-S50 |
Type | Analog Input Module |
Number of Channels | 8 channels |
Input Signal | 4 to 20 mA |
Accuracy | ±0.1% of span |
Resolution | 16 bits |
Input Impedance | Approx. 250 Ohms |
Power Supply Voltage | 24 V DC (supplied from baseplate) |
Operating Temperature | -20°C to +70°C |
Storage Temperature | -40°C to +85°C |
Humidity | 5% to 95% RH (non-condensing) |
Dimensions | 107.5 × 32.8 × 130 mm |
Weight | 0.3 kg |
Isolation | Isolated between channels and system |
Installation | Mounted on N-IO baseplate |
Certification | CE, UL, CSA, ATEX (depending on region) |
Product Applications
-
Petrochemical Plants – For real-time process monitoring and safety interlocks.
-
Power Generation Facilities – Used for continuous monitoring of pressure, flow, and temperature variables.
-
Pharmaceutical Manufacturing – Ensures precise environmental and process control for quality assurance.
-
Water Treatment Systems – Monitors key quality parameters in municipal and industrial water management.
-
Food & Beverage Industry – Helps in temperature and flow rate regulation during batch processing.
-
Pulp and Paper Mills – Manages analog signal input for automated paper production processes.
Compatible Models
The Yokogawa AAI835-S50 is designed for compatibility with a variety of other modules in the N-IO and ProSafe-RS systems. Below are several commonly used compatible models:
-
Yokogawa AAI141-S50 – Analog Input Module (16 channels)
-
Yokogawa AAI543-S50 – Analog Output Module
-
Yokogawa ADV151-P03 – Digital Input Module
-
Yokogawa ADV551-P03 – Digital Output Module
-
Yokogawa AAR181-S50 – Remote I/O Network Interface
-
Yokogawa CP451-50 – Processor Module
Installation Instructions
-
Power Down System: Ensure the system is powered off or in maintenance mode.
-
Insert Module: Align the AAI835-S50 with the designated N-IO baseplate slot and insert until it clicks into place.
-
Secure the Module: Use the locking levers to firmly secure the module.
-
Connect Field Wiring: Attach signal cables to the terminal block according to the wiring diagram provided in the installation manual.
-
Check Grounding: Verify proper grounding to reduce noise interference.
-
Perform Diagnostics: Run initial self-checks via the Yokogawa engineering tool to ensure signal integrity and correct installation.
-
Power On and Configure: Turn on the system and configure the module via the control software (CENTUM VP or ProSafe-RS).
Related Models (Same Series or Similar)
Model | Description | Channels | Input Type | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
AAI141-S50 | Analog Input Module | 16 | 4–20 mA | 24V DC | 130 x 27.4 x 130 | 140 g |
AAI543-S50 | Analog Output Module | 8 | 4–20 mA | 24V DC | 130 x 27.4 x 130 | 160 g |
ADV151-P03 | Digital Input Module | 16 | 24V DC | 24V DC | 130 x 27.4 x 130 | 135 g |
ADV551-P03 | Digital Output Module | 16 | 24V DC | 24V DC | 130 x 27.4 x 130 | 135 g |
AAR181-S50 | Remote I/O Interface Module | N/A | Ethernet | 24V DC | 130 x 27.4 x 130 | 155 g |
AAM50 | Multiplexer Module | 32 | Analog | 24V DC | 130 x 27.4 x 130 | 150 g |
Popular Yokogawa Models
Model | Description | Type | Channels | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
AAI835-S50 | Analog Input Module | Analog Input | 8 | 24V DC | 130 x 27.4 x 130 | 150 g |
AAI141-S50 | Analog Input Module | Analog Input | 16 | 24V DC | 130 x 27.4 x 130 | 140 g |
AAI543-S50 | Analog Output Module | Analog Output | 8 | 24V DC | 130 x 27.4 x 130 | 160 g |
ADV151-P03 | Digital Input Module | Digital Input | 16 | 24V DC | 130 x 27.4 x 130 | 135 g |
ADV551-P03 | Digital Output Module | Digital Output | 16 | 24V DC | 130 x 27.4 x 130 | 135 g |
CP451-50 | Processor Module | CPU | N/A | 24V DC | 130 x 45 x 130 | 180 g |
AAR181-S50 | Remote I/O Network Interface Module | Interface | N/A | 24V DC | 130 x 27.4 x 130 | 155 g |
NFAI143-S50 | AI Functional Safety Input Module | Analog Input (Safety) | 8 | 24V DC | 130 x 27.4 x 130 | 150 g |
Frequently Asked Questions (FAQ)
Q1: What kind of signals can the AAI835-S50 receive?
A1: The AAI835-S50 supports 4 to 20 mA analog current input signals, commonly used in industrial sensors and transmitters.
Q2: Is the AAI835-S50 compatible with CENTUM VP systems?
A2: Yes, it is fully compatible with Yokogawa’s CENTUM VP DCS, as well as ProSafe-RS safety systems.
Q3: Can I hot-swap the AAI835-S50 without shutting down the system?
A3: Yes, it supports hot-swapping, allowing the module to be replaced without halting operations.
Q4: Does the AAI835-S50 offer electrical isolation?
A4: Yes, it features channel-to-channel and channel-to-system electrical isolation to ensure signal integrity and system safety.
Q5: What certifications does the AAI835-S50 hold?
A5: Depending on the region, it complies with CE, UL, CSA, and ATEX standards for industrial automation equipment.
Q6: How can I perform diagnostics on this module?
A6: Built-in diagnostics can be accessed through Yokogawa’s engineering tools for fault detection, calibration validation, and wiring checks.
Yokogawa AAI835-S50 Analog I/O Modules