Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Introduction – Yokogawa AAB841-S00 S2
The Yokogawa AAB841-S00 S2 is a high-performance I/O module engineered for use within the Yokogawa CENTUM VP control system. As a robust component of the Field Control Station (FCS), it is designed to deliver reliable data acquisition and control functions across a wide range of industrial automation applications. Known for its stable operation, precision engineering, and modular structure, this module supports seamless integration and high-speed communication with various field devices.
The AAB841-S00 S2 represents Yokogawa’s dedication to quality, offering long-term durability and performance even under harsh industrial environments. This model features S2 redundancy support, enhancing system availability and fault tolerance critical for mission-critical processes in oil & gas, petrochemical, power, and manufacturing sectors.
Product Advantages
-
High Reliability: Built with industrial-grade components to ensure durability and long-term operational stability in demanding environments.
-
Redundancy Support: Incorporates dual-redundant S2 architecture, enabling uninterrupted performance and reduced system downtime.
-
Enhanced Communication: Supports high-speed data exchange with field devices via the Vnet/IP network for optimized real-time control.
-
Modular Design: Facilitates easy installation, replacement, and future expansion without extensive system reconfiguration.
-
Diagnostic Capabilities: Equipped with advanced self-diagnostic and fault monitoring features for proactive maintenance and reduced unplanned outages.
-
Wide Compatibility: Compatible with a wide range of I/O units and controllers under the Yokogawa CENTUM VP system.
Technical Specifications
Parameter | Details |
---|---|
Model Number | AAB841-S00 S2 |
Manufacturer | Yokogawa Electric Corporation |
Module Type | AI/AO Digital I/O Communication Module |
Supported System | CENTUM VP Field Control Station |
Communication Interface | Vnet/IP |
Redundancy | Supported (S2 Dual Redundant Configuration) |
Voltage | 24 VDC (nominal) |
Power Consumption | 3.0 W |
Weight | 0.3 kg |
Dimensions | 107.5 × 32.8 × 130 mm |
Mounting | DIN Rail / Baseplate Mounting |
Operating Temperature | 0°C to 55°C |
Storage Temperature | -20°C to 70°C |
Relative Humidity | 5% to 95% RH (non-condensing) |
EMC & Safety Compliance | CE, RoHS, CSA, UL |
Applications
The Yokogawa AAB841-S00 S2 module is suitable for a broad spectrum of industrial applications, including:
-
Oil & Gas: Process control for upstream and downstream operations.
-
Petrochemical & Chemical Plants: Monitoring and controlling chemical reactions and refinery operations.
-
Power Generation: Turbine control, boiler automation, and energy distribution.
-
Water & Wastewater Management: Flow monitoring, filtration control, and pumping station management.
-
Pharmaceutical: Batch control systems and critical environment monitoring.
-
Pulp & Paper: Control of pulp processing, drying, and cutting lines.
Compatible Models for System Integration
The AAB841-S00 S2 module works efficiently with the following Yokogawa models within a CENTUM VP system:
-
AFV10D – Vnet/IP Interface Module
-
ADV151 – Analog Input Module
-
ADV561 – Analog Output Module
-
ADV551 – Digital Output Module
-
ADV141 – Digital Input Module
-
AMM12C – Multi-point Analog I/O Module
These modules collectively form a complete, scalable process control environment that ensures reliable and flexible system architecture.
Installation Instructions
-
Preparation
-
Ensure power to the Field Control Station is turned off.
-
Verify the compatibility of the baseplate with the AAB841-S00 S2 module.
-
-
Mounting the Module
-
Position the module on the designated baseplate slot or DIN rail.
-
Push the module firmly until it is securely locked in place.
-
-
Connecting Cables
-
Connect the communication cable to the Vnet/IP terminal.
-
Attach the power cable to the 24 VDC input port.
-
-
Verification
-
Power on the control station.
-
Confirm proper module operation using engineering software (e.g., Yokogawa’s System View).
-
Check status indicators for normal operation (LED should be steady green).
-
-
Configuration
-
Load the I/O configuration file in the CENTUM VP system.
-
Perform a loop check to validate communication and data acquisition.
-
-
Final Inspection
-
Secure all wiring.
-
Document the installation details for maintenance records.
-
6 Related Yokogawa Models
Model | Description | Voltage | Weight | Dimensions (mm) |
---|---|---|---|---|
ADV151 | Analog Input Module | 24 VDC | 0.27 kg | 27.2 × 130 × 170 |
ADV551 | Digital Output Module | 24 VDC | 0.28 kg | 27.2 × 130 × 170 |
ADV561 | Analog Output Module | 24 VDC | 0.30 kg | 27.2 × 130 × 170 |
ADV141 | Digital Input Module | 24 VDC | 0.26 kg | 27.2 × 130 × 170 |
AFV10D | Vnet/IP Interface Module | 24 VDC | 0.31 kg | 27.2 × 130 × 170 |
AMM12C | Multi-point Analog I/O Module | 24 VDC | 0.32 kg | 27.2 × 130 × 170 |
8 Popular Yokogawa Models
Model | Description | Voltage | Weight | Dimensions (mm) |
---|---|---|---|---|
CP451-50 | Processor Module for FCS | 24 VDC | 0.45 kg | 40 × 130 × 180 |
NFAI143-S50 | Analog Input FIO Module | 24 VDC | 0.28 kg | 27.2 × 130 × 170 |
F3LE11-0T | Digital I/O Module for FA-M3 | 5 VDC | 0.20 kg | 33 × 98 × 140 |
NFDV161-P50 | Digital Output FIO Module | 24 VDC | 0.29 kg | 27.2 × 130 × 170 |
AAI543-H00 | Analog Input Module with HART | 24 VDC | 0.26 kg | 27.2 × 130 × 170 |
AAI841-H00 | Analog Output Module with HART | 24 VDC | 0.30 kg | 27.2 × 130 × 170 |
AAI141-S00 | Standard Analog Input Module | 24 VDC | 0.25 kg | 27.2 × 130 × 170 |
AAR181-S00 | Remote I/O Node Interface | 24 VDC | 0.40 kg | 27.2 × 130 × 170 |
FAQ – Frequently Asked Questions
Q1: What is the primary function of the AAB841-S00 S2 module?
A1: The AAB841-S00 S2 functions as a communication interface module that connects I/O units to the CENTUM VP control network via Vnet/IP, supporting redundant configuration for high availability.
Q2: Can the module operate in high-temperature environments?
A2: Yes, the AAB841-S00 S2 is rated to operate within a temperature range of 0°C to 55°C, suitable for most industrial settings.
Q3: Is this module hot-swappable?
A3: No, the module must be installed or replaced when the system is powered down to ensure safety and prevent system damage.
Q4: How can I verify if the module is operating correctly?
A4: Upon system startup, verify LED indicators for steady green lights and use Yokogawa diagnostic tools in the CENTUM VP system for deeper status monitoring.
Q5: What kind of maintenance is required for this module?
A5: Routine visual inspection, checking for dust, loose wiring, and verifying LED status. Periodic diagnostic checks through software are also recommended.
Q6: Can the AAB841-S00 S2 be used with non-Yokogawa systems?
A6: It is optimized for use exclusively within Yokogawa’s CENTUM VP architecture and is not compatible with third-party DCS or PLC systems.