Product Introduction
The Honeywell 8U-PWCNTA 51307038-100 is a high-performance power controller module specifically engineered for the TDC3000 system environment. It plays a vital role in ensuring stable and regulated power distribution to various nodes within Honeywell’s distributed control systems (DCS). By offering enhanced power management capabilities, it contributes to the reliable performance and operational integrity of industrial automation systems.
This module is designed to work seamlessly with Honeywell’s Universal Control Network (UCN) and Process Manager I/O systems, delivering robust and dependable power control in complex industrial environments. Its intelligent interface and precision manufacturing allow it to operate under demanding conditions with minimal maintenance.
Product Advantages
-
Optimized for TDC3000 Systems: Seamless integration and optimized performance in Honeywell’s legacy DCS architecture.
-
Reliable Power Regulation: Ensures consistent voltage supply to critical system components, reducing downtime and power instability.
-
High Build Quality: Industrial-grade components and materials ensure durability and long-term performance.
-
Plug-and-Play Compatibility: Easy installation and replacement within existing Honeywell control cabinets without the need for reconfiguration.
-
Enhanced Fault Detection: Built-in diagnostics and status indicators enable quick identification of power issues.
-
Compact and Modular Design: Saves space and supports scalable system architecture in control rooms and cabinets.
Technical Specifications
Parameter | Details |
---|---|
Model Number | 8U-PWCNTA |
Part Number | 51307038-100 |
System Compatibility | Honeywell TDC3000, UCN |
Power Supply | 24 VDC (nominal) |
Voltage Range | 18–30 VDC |
Power Consumption | ≤ 15 W |
Input/Output Connections | Screw terminal blocks |
Status Indicators | LED indicators for power and fault |
Communication | UCN interface |
Mounting Type | Panel or DIN rail mounting |
Operating Temperature | 0°C to +60°C |
Storage Temperature | -40°C to +85°C |
Relative Humidity | 5% to 95% non-condensing |
Dimensions | 367 x 363 x 20 mm |
Weight | 0.72 kg |
Enclosure Protection | IP20 |
Compliance Certifications | CE, UL, CSA |
Applications
-
Distributed Control Systems (DCS): Integral component in Honeywell’s TDC3000 environments to manage power flow to controllers and I/O.
-
Power Distribution Units: Used for safe and efficient power routing in large-scale automation systems.
-
Refineries and Petrochemical Plants: Provides reliable power supply in mission-critical systems.
-
Power Plants: Ensures consistent power delivery in SCADA-linked control rooms.
-
Pharmaceutical and Chemical Processing: Facilitates uninterrupted operation of production line control systems.
-
Industrial Automation Cabinets: Designed for use in enclosed panel systems for compact installation.
Compatible Models
-
Honeywell UCN Interface Modules
-
Honeywell TDC3000 I/O Modules
-
Honeywell PM I/O Assemblies
-
Honeywell 8U-BXCB20
-
Honeywell 8U-TDODA1
-
Honeywell 8U-TCNTA1
-
Honeywell 8C-PAINA1
These modules are often used together within the same system environment to ensure a cohesive and reliable automation platform.
Installation Instructions
-
Preparation: Ensure all system power is turned off and proper anti-static handling measures are in place.
-
Mounting: Secure the module in the control cabinet using the designated DIN rail or panel mount locations.
-
Wiring: Connect the incoming 24 VDC power supply to the input terminals, and distribute power through the output terminals.
-
Interface Connection: Attach UCN communication cables as required for system integration.
-
Power-Up and Testing: Once all wiring is complete, power on the system and check LED indicators for normal operation.
-
Final Checks: Validate that the connected devices are receiving proper voltage and that no fault conditions are indicated.
6 Related Models from Same Series
Model | Part Number | Voltage | Power | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|---|
8U-TCNTA1 | 51307070-100 | 24 VDC | 12 W | 290 x 110 x 100 | 1.80 |
8U-TDODA1 | 51307039-100 | 24 VDC | 10 W | 290 x 110 x 100 | 1.70 |
8U-BXCB20 | 51307020-100 | 24 VDC | 8 W | 290 x 110 x 90 | 1.60 |
8U-PAINA1 | 51307050-100 | 24 VDC | 10 W | 290 x 110 x 100 | 1.85 |
8U-PAONA1 | 51307060-100 | 24 VDC | 12 W | 290 x 110 x 100 | 1.90 |
8U-TAIXA1 | 51307080-100 | 24 VDC | 11 W | 290 x 110 x 100 | 1.88 |
8 Popular Honeywell Models
Model | Part Number | Application | Voltage | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|---|
CC-PCF901 | 51405047-175 | Fieldbus Interface Module | 24 VDC | 280 x 106 x 100 | 1.95 |
CC-TDOR11 | 51405040-175 | Digital Output Module | 24 VDC | 280 x 106 x 100 | 1.88 |
CC-TFB811 | 51405039-175 | Analog Input Module | 24 VDC | 280 x 106 x 100 | 1.90 |
CC-TAIX11 | 51405038-175 | Analog Input Interface | 24 VDC | 280 x 106 x 100 | 1.85 |
CC-TDIL01 | 51405042-175 | Digital Input Module | 24 VDC | 280 x 106 x 100 | 1.87 |
CC-PDIL01 | 51405040-175 | Digital Input (24 VDC) | 24 VDC | 280 x 106 x 100 | 1.89 |
CC-PAOH01 | 51405047-100 | Analog Output Module | 24 VDC | 280 x 106 x 100 | 1.93 |
CC-PAIH01 | 51405039-176 | HART Analog Input Module | 24 VDC | 280 x 106 x 100 | 1.91 |
FAQ (Frequently Asked Questions)
Q1: What is the primary function of the 8U-PWCNTA module?
A1: It serves as a power control and distribution module for Honeywell’s TDC3000 systems, ensuring regulated power delivery to critical components.
Q2: Is the 8U-PWCNTA compatible with other DCS platforms besides TDC3000?
A2: It is specifically optimized for Honeywell’s TDC3000 platform, and its full functionality is not guaranteed with non-Honeywell systems.
Q3: Can the module be replaced while the system is powered?
A3: No, it is recommended to power down the system completely before installation or replacement to avoid damage.
Q4: How can I identify if the module is faulty?
A4: Built-in LED indicators provide fault status. A red or unlit LED typically signifies a problem.
Q5: What type of maintenance does the 8U-PWCNTA require?
A5: Routine inspection for dust, corrosion, and connector tightness is recommended. No moving parts mean minimal wear.
Q6: Is this product still available from Honeywell directly?
A6: While it may be limited in availability through Honeywell due to legacy status, it can still be sourced through certified distributors and automation resellers.
Honeywell 8U-PWCNTA 51307038-100 Power Supply Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |