HIMA F3108 Detailed Product Profile
Product Introduction
The HIMA F3108 is a high-performance relay module designed for critical industrial applications requiring secure and reliable signal switching. As part of HIMA’s industry-renowned safety systems, the F3108 ensures fault-tolerant operation, offering excellent durability under extreme environmental conditions. Engineered in compliance with stringent international safety standards such as IEC 61508 and EN 50156, it serves an indispensable role in functional safety architectures, particularly in process industries like oil & gas, chemical, power generation, and more.
The HIMA F3108’s compact structure, rugged design, and excellent compatibility with HIMA’s HIMax and HIQuad X platforms make it an optimal choice for integration into new and existing systems, maintaining the highest levels of operational reliability.
Product Advantages
-
High Reliability: Built for continuous operation under harsh conditions, ensuring minimal downtime and system stability.
-
Safety Certified: Meets SIL 3 standards according to IEC 61508, guaranteeing top-tier functional safety performance.
-
Wide Compatibility: Seamless integration with HIMA’s HIMax, HIQuad, and Planar4 safety controllers.
-
Compact Design: Space-saving modular format facilitates easy installation into densely packed cabinets.
-
Long Service Life: Advanced component selection and robust manufacturing processes yield an extended operational lifespan.
-
Flexible Application Range: Ideal for a variety of safety-critical systems such as emergency shutdown systems (ESD), fire & gas systems (F&G), and turbine control systems.
Technical Specifications
Parameter | Specification |
---|---|
Model Number | F3108 |
Dimensions | 100 x 25 x 120 mm |
Weight | 0.15 kg |
Supply Voltage | 24 V DC ±10% |
Input Signal Voltage | 24 V DC |
Output Contact Rating | 30 V DC / 250 V AC, 6 A (resistive load) |
Power Consumption | Approx. 2 W |
Operating Temperature | -20°C to +60°C |
Storage Temperature | -40°C to +85°C |
Relative Humidity | 5% to 95% (non-condensing) |
Protection Class | IP20 |
Certification | SIL 3 (IEC 61508) |
Installation | Standard 35 mm DIN Rail Mounting |
Product Applications
The HIMA F3108 relay module is widely employed across numerous sectors where process and functional safety are paramount:
-
Emergency Shutdown Systems (ESD): Initiating safe shutdowns during critical situations.
-
Fire and Gas Detection Systems (F&G): Ensuring safe and reliable operation of alarm and mitigation measures.
-
Turbine Control Systems: Providing critical control and shutdown capabilities.
-
Chemical Processing Plants: Managing high-risk process controls to prevent hazardous events.
-
Oil & Gas Industry: Assuring safe upstream and downstream operations.
-
Power Generation Facilities: Enabling safe load shedding and protective functions.
Compatible Models for Use
The HIMA F3108 is often paired with the following devices for integrated safety systems:
-
HIMA HIMax Series Controllers (e.g., X-CPU01, X-HS01)
-
HIMA HIQuad X Series (e.g., F8650X, F8627X)
-
HIMA Planar4 Series
-
HIMA F35 Safety System
-
HIMA S6200 I/O Modules
-
HIMA C6200 Communication Modules
Installation Instructions
-
Pre-Installation Checks: Ensure that the module is free from physical damage and verify its compatibility with the intended system configuration.
-
Mounting: Install the F3108 module on a standard 35 mm DIN rail within an enclosure that provides adequate protection against environmental factors.
-
Wiring: Connect input and output terminals according to the system’s electrical schematics, ensuring adherence to HIMA wiring standards.
-
Power Connection: Supply regulated 24 V DC power to the module, ensuring correct polarity and secure fastening.
-
Commissioning: Perform a continuity and insulation resistance test prior to energizing the system.
-
Verification: After installation, validate the module’s functionality through system diagnostics and operational testing to ensure correct integration into the safety circuit.
-
Documentation: Update the project documentation to reflect the installation and commissioning status of the module.
Related Models Recommendation
Model | Dimensions (mm) | Weight | Supply Voltage | Key Features |
---|---|---|---|---|
HIMA F3117 | 100 x 80 x 20 | 155 g | 24 V DC | Safety relay for digital outputs |
HIMA F3221 | 100 x 80 x 20 | 160 g | 24 V DC | Digital input module, redundant |
HIMA F3236 | 100 x 80 x 20 | 150 g | 24 V DC | Analog input module, isolated |
HIMA F8621X | 100 x 160 x 20 | 300 g | 24 V DC | Advanced safety controller |
HIMA F8650X | 100 x 160 x 20 | 320 g | 24 V DC | CPU for safety-related applications |
HIMA F7126 | 100 x 80 x 20 | 140 g | 24 V DC | Relay module with status monitoring |
Popular HIMA Models Recommendation
Model | Dimensions (mm) | Weight | Supply Voltage | Key Features |
---|---|---|---|---|
HIMA X-CPU01 | 130 x 160 x 40 | 500 g | 24 V DC | Main CPU unit for HIMax platform |
HIMA F7133 | 100 x 80 x 20 | 150 g | 24 V DC | Digital output module, fail-safe |
HIMA F6705 | 100 x 80 x 20 | 145 g | 24 V DC | Communication module |
HIMA F8627X | 100 x 160 x 20 | 310 g | 24 V DC | Advanced safety CPU |
HIMA X-SB01 | 130 x 160 x 40 | 480 g | 24 V DC | System bus module for HIMax systems |
HIMA K7213 | 100 x 80 x 20 | 130 g | 24 V DC | Interface module for analog signals |
HIMA F8652X | 100 x 160 x 20 | 315 g | 24 V DC | High-capacity safety CPU |
HIMA F8653X | 100 x 160 x 20 | 325 g | 24 V DC | Advanced safety CPU with redundancy |
HIMA F3108 FAQs (Q&A Format)
Q1: What certifications does the HIMA F3108 meet?
A1: The F3108 is certified to SIL 3 according to IEC 61508 and complies with EN 50156 standards for safety-related control systems.
Q2: Can the F3108 module be used in high-temperature environments?
A2: Yes, the F3108 operates reliably within a temperature range of -20°C to +60°C, making it suitable for a wide range of industrial environments.
Q3: Is the HIMA F3108 compatible with the HIMax platform?
A3: Absolutely, the F3108 module is fully compatible with the HIMax platform and other HIMA systems like HIQuad X and Planar4.
Q4: How should I mount the HIMA F3108?
A4: The module should be mounted on a 35 mm DIN rail inside a suitable protective enclosure, following standard installation guidelines.
Q5: What maintenance is required for the F3108?
A5: Routine maintenance includes visual inspections for damage, verification of secure connections, and periodic functional testing in accordance with safety management plans.
Q6: What happens if the supply voltage deviates from the specified range?
A6: If the 24 V DC supply voltage deviates beyond ±10%, it may affect the operational stability of the module, potentially triggering diagnostic alarms or a safe-state shutdown.