Product Introduction: ABB Bailey IIADP02 6638627D1
The ABB Bailey IIADP02 6638627D1 is a robust and reliable Analog Input Module designed for use in the Infi 90 Distributed Control System (DCS). It serves as a critical component for interfacing analog signals from field devices into the control system for monitoring and control purposes. As part of the ABB Bailey INFI 90 family, this module offers exceptional performance and long-term durability in industrial environments.
The IIADP02 module processes differential analog input signals and converts them into digital signals to be interpreted by the system’s controller. It supports multiple channels and ensures high accuracy and fast response, making it suitable for applications requiring precise analog measurement and integration.
This module is built to operate in harsh conditions while maintaining stability and integrity, aligning with ABB’s reputation for producing high-reliability automation equipment.
Product Advantages
-
High Precision Analog Input: Supports differential input for enhanced accuracy and noise immunity.
-
Rugged Design: Built for operation in demanding industrial environments with excellent electrical and thermal stability.
-
Seamless System Integration: Fully compatible with ABB’s INFI 90 DCS platform and seamlessly integrates with other modules.
-
Multiple Channel Support: Allows multiple analog input channels, optimizing space and reducing installation costs.
-
Long Product Lifecycle: Engineered for durability and long-term operational consistency.
-
Ease of Maintenance: Designed with diagnostic indicators and modular construction for easier troubleshooting and replacement.
Technical Specifications
Parameter | Description |
---|---|
Model | IIADP02 |
Part Number | 6638627D1 |
Manufacturer | ABB Bailey |
System Compatibility | INFI 90 DCS |
Number of Channels | 8 differential analog inputs |
Input Signal Range | 0 to 5 V / 0 to 10 V / 4-20 mA (configurable) |
Conversion Type | Analog to Digital |
Accuracy | ±0.1% of full scale |
Input Impedance | >1 MΩ |
Isolation | Channel-to-Channel and Channel-to-Ground |
Dimensions | 72 x 144 x 381 mm |
Weight | 1.6 kg |
Operating Voltage | 24 VDC (nominal) |
Power Consumption | 5 Watts |
Operating Temperature | 0°C to +60°C |
Storage Temperature | -40°C to +85°C |
Mounting | DIN rail or panel mount |
Certifications | CE, UL, CSA, RoHS |
Applications
The ABB IIADP02 module is widely deployed in the following applications:
-
Power Plants – For monitoring analog process variables such as temperature, pressure, and flow.
-
Petrochemical Plants – Integration with pressure transmitters, flow meters, and control valves.
-
Manufacturing Automation – Accurate analog input acquisition for factory automation processes.
-
Water and Wastewater Treatment – Monitoring of pH levels, turbidity, and flow rates.
-
Pharmaceutical Production – Ensuring compliance and monitoring sensitive production metrics.
-
Oil & Gas Industry – Capturing precise analog signals in hazardous environments.
Compatible Models
The IIADP02 module is typically used in combination with the following ABB Bailey modules:
-
IMASI23 – Analog Input Module
-
IMDSI12 – Digital Input Module
-
IMRIO02 – Remote I/O Module
-
INICT13A – Network Interface Module
-
NTCL01 – Termination Module
-
NBIO01 – Bus Interface Module
Installation Instructions
-
Power Down the System: Ensure that all power sources are turned off before beginning installation.
-
Mounting: Secure the IIADP02 module on a DIN rail or within the system cabinet according to the specified dimensions.
-
Wiring: Connect field devices to the analog input terminals on the IIADP02. Follow ABB’s wiring diagram to avoid polarity issues or short circuits.
-
Communication Setup: Connect the module to the INFI 90 system bus using appropriate communication cables.
-
Configuration: Use the system configuration software to define channel parameters, such as input type (voltage/current) and scaling.
-
Power Up and Test: Once all connections are verified, power up the system and run diagnostic tests to confirm module operation.
-
Calibration (if required): Calibrate the analog input channels using ABB calibration tools for enhanced accuracy.
6 Related Models in the Same Series
Model | Description | Input Type | Channels | Voltage | Weight | Dimensions (mm) |
---|---|---|---|---|---|---|
IMASI23 | Analog Input Module | Voltage/Current | 16 | 24 VDC | 0.75 kg | 120 × 260 × 60 |
IMDSI12 | Digital Input Module | Digital | 16 | 24 VDC | 0.70 kg | 110 × 250 × 55 |
IMRIO02 | Remote I/O Interface Module | Mixed | – | 24 VDC | 0.80 kg | 125 × 270 × 60 |
INICT13A | Network Interface Controller | – | – | 24 VDC | 0.65 kg | 115 × 240 × 50 |
INNIS21 | Communication Module for Ethernet | Ethernet | – | 24 VDC | 0.85 kg | 130 × 265 × 65 |
NTCL01 | Termination Module | – | – | – | 0.40 kg | 90 × 200 × 40 |
8 Popular ABB Models
Model | Function | System | Voltage | Weight | Dimensions (mm) |
---|---|---|---|---|---|
IMASI23 | Analog Input Module | INFI 90 | 24 VDC | 0.75 kg | 120 × 260 × 60 |
IMMFP12 | Multi-function Processor Module | Symphony DCI | 24 VDC | 1.2 kg | 140 × 280 × 70 |
INICT13A | Network Interface Module | INFI 90 | 24 VDC | 0.65 kg | 115 × 240 × 50 |
IMSED01 | Sequence of Events Detection Module | INFI 90 | 24 VDC | 0.78 kg | 125 × 265 × 60 |
INNIS21 | Ethernet Communication Interface | INFI 90 | 24 VDC | 0.85 kg | 130 × 265 × 65 |
IMMFP11 | Controller Processor Module | Symphony DCI | 24 VDC | 1.0 kg | 135 × 275 × 65 |
NTCL01 | Termination Module | INFI 90 | – | 0.40 kg | 90 × 200 × 40 |
NBIO01 | Bus Interface Module | INFI 90 | 24 VDC | 0.72 kg | 120 × 260 × 55 |
Frequently Asked Questions (FAQ)
Q1: What is the primary function of the IIADP02 module?
A1: The IIADP02 is an analog input module that converts analog signals (voltage or current) from field instruments into digital signals for processing by the INFI 90 control system.
Q2: How many analog inputs does the IIADP02 support?
A2: It supports 8 differential analog input channels, ensuring accurate and isolated signal acquisition.
Q3: Can I use the IIADP02 module with other ABB control systems?
A3: The IIADP02 is specifically designed for use within the ABB INFI 90 DCS. For other ABB platforms, different modules may be required.
Q4: What kind of input signals can the IIADP02 handle?
A4: It can handle 0-5 V, 0-10 V, and 4-20 mA input signals, which can be configured as per application needs.
Q5: Is the module hot-swappable?
A5: No, the IIADP02 should be installed and removed only when the system is powered down to avoid damage or data loss.
Q6: How can I ensure the module is functioning correctly after installation?
A6: Run system diagnostics through the configuration software and observe status LEDs for any fault or communication error indications.
ABB Bailey IIADP02 6638627D1 Alarm display panel
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |